2.0 GENERAL
Gas installation to conform to local codes, or in absence of local codes, with the National Fuel
Gas Code - ANSI Z223.1/NFPA 54. In Canada installation to be in accordance with the Natural
Gas and Propane Installation Code, CSA B149.1. and or local codes.
1.
The appliance and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at pressures in excess of ½ psig
(3.45 kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psig (3.45 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70. In Canada, installation must be in
accordance with the Canadian Electrical Code CSA C22.2.
WARNING: Electrical grounding instructions - Units come equipped
with a three-prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. (120 VOLT UNITS ONLY)
WIRING DIAGRAM FOR APPLIANCE IS LOCATED ON RIGHT HAND SIDE PANEL OF THE
COOKER CABINET.
2.1 EXHAUST FANS AND CANOPIES:
Canopies are set over ranges, ovens, kettles, etc., for ventilation purposes. It is
recommended that a canopy extend 6" past the appliance and be located 6' 6" from the
floor. Filters should be installed at an angle of 45 degrees or more with the horizontal.
This position prevents dripping of grease and facilitates collecting the run-off grease in a
drip pan, usually installed with the filter. A strong exhaust fan tends to create a vacuum in
the room and may interfere with burner performance or may extinguish pilot flames.
Makeup air openings approximately equal to the fan area will relieve such vacuum. In
case of unsatisfactory performance on any appliance, check with the exhaust fan in the
“OFF” position.
2.2 WALL EXHAUST FAN:
The exhaust fan should be installed at least two feet above the vent opening at the top of
the unit.