INSTALLATION AND OPERATION MANUAL AND PARTS LIST,
MODELS: STHE-7-TGG, STHE-12-TGG, STHE-16-TGG
PART NUMBER 10225R0
31
2010-09-07
Buzzer
If the buzzer does not sound at the termination of the operator-selected timer setting (timer dial
returned to “0-Minute” position), the fault may be a defective buzzer. Buzzer operation is
verified using an AC volt-meter at buzzer coil connections with input power on and selector
switch and coinciding timer dial set at the “0-Minute” position. If voltage is 120 volts, the fault is
in the buzzer, which must be replaced. If 120 volts is not present, the fault is in the wiring or
control components (timer or selector switch).
Wiring
Using an ohmmeter, wiring continuity between the connections shown on the wiring diagram is
readily verified. This is best done in stages, removing only those wires required for each continuity
check. As each lead is replaced, it should be checked for evidence of corrosion, and cleaned if
necessary. All leads must be tightly attached so as to provide a good electrical connection.
PROBLEM
PROBABLE CAUSE
REMEDY
1.
D
OOR LEAKS
.
a. Damaged Door Gasket.
Check gasket for cuts and re-place.
b. Door latch.
Adjust tension
c. Door hand.
Adjust tension
2.
W
ATER FLOWS INTO COOKING
COMPARTMENT
.
a. Level probe short circuited.
Check and correct
b. Scale build-up on probe.
Clean all probes
c. Water fill solenoid valve.
Plugged, defective, clean or replace
NOTE THESE PROBLEMS ARE AN INDICATION OF SEVER WATER CONDITIONS WHICH SHOULD BE CORRECTED IMMEDIATELY TO AVOID
DAMAGE TO THE COMPONENTS AND PERFORMANCE OF THE STEAMER
.
CALL
YOUR
SERVICE
AGENCY
FOR
ASSISTANCE.
3.
W
ATER ACCUMULATES IN
COMPARTMENT
.
a. Plugged compartment drain
Remove screen and clean drain line
4.
W
ATER FLOWS INTO DRAIN DURING
SHUT DOWN
.
a. Thermostatic cooling valve does
not close.
Check valve for foreign material, or
damage
5.
W
ATER NOT BEING SUPPLIED TO
G
ENERATOR
.
a. Water supply off
Check in coming water valve is on
b. Supply water pressure too low
Call supply agency
c. Defective water solenoid valve
Replace or clean
d. Level Probe shorted
Check and correct
e. Defective water level control
Replace
f. Drain valve is open
Check valve, clean or replace