INSTALLATION AND OPERATION MANUAL AND PARTS LIST,
MODELS: STHE-7-TGG, STHE-12-TGG, STHE-16-TGG
PART NUMBER 10225R0
16
2010-09-07
4.0 OPERATION INSTRUCTIONS
(Continued)
Drip/Spill Trough Drainage
The Pressureless Steam Cookers have a drip/spill trough below the cooking compartment door.
It will catch any condensate gathering on the front of the unit when the door is opened.
WARNING: The steamer and its parts are hot. Use care when
operating, cleaning or servicing the steamer. The cooking
compartment contains live steam. Stay clear when opening door.
CAUTION: An obstructed drain can cause personal injury or
property damage.
CONTROLS
1.
Ignition Light
When lit, indicates burners have been ignited
and are heating the steam generator tank.
2. Ready Pilot Light
When lit, indicates steam generator has reached
205º Fahrenheit (97º Celsius) and is ready for
the cooking cycle.
3. Cooking Pilot Light
When lit, indicates that a cooking cycle is in
progress.
4. Timer /Constant Steam
Set the cooking time (0 to 60 minutes) - steam
cooking will begin when the door is closed. The
cooking cycle will be interrupted if the door is
opened during the cooking cycle; resume
cooking by closing the door. Constant Steam -
For continuous cooking.
5. Main Power Switch
DELIME
Closes the drain valve while CLR liquid is being poured into
the steam generator during the Delime procedure. Amber
light will ignite on the main power switch.
ON
The steam generator will automatically fill and begin heating to the pre-set temperature. Red light
will ignite on the main power switch.
OFF
The steam generator will drain. No lights.
6. Buzzer
Signals end of cooking period (not shown).