EDITING Windows
on the Edit window is possible edit all parameters of the Input and output Output channel, save and
load configuration on the sw PC, copy the input channel to another input channel, insert and change a
User password in order to lock/unlock the interface, link the channel and see the current version of
the firmware and software.
On the ALL Editing Windows, the Top Bar is fixed and shows ever the several available “tools'' useful
for the User to manage the Editing Job so as to save it on Pc or within the unit.
TOOL BAR
Load
: Load a previously saved Full Configuration from a defined Pc directory. The configuration
loaded will be the one edited with its parameters set on the several editing windows. The
configuration loaded is containing the ALL parameters set in the several Editing Windows
Save
: Save the current Full Configuration (the all parameters set within the all Editing Windows) into a
defined Pc directory. The saved configuration is containing the ALL parameters set in the several
Editing Windows
Store
: Save the current Full Configuration (the all parameters set within the all Editing Windows) into
one of 16 available locations within the
LPP260A
. The saved configuration is containing the ALL
parameters set in the several Editing Windows and can be recalled also from the unit's front panel.
Recall
: Load a previously saved Full Configuration from one of 16 available locations within the
LPP260A
. The configuration loaded will be the one edited with its parameters set on the several
editing windows.
Copy
(located after Recall): tool for copying the all parameters of one input channel to an other one.
The Phase Correction FIR, available on each Input Path, are not included in this copy tool.
Copy
(located before Default): tool for copying the all parameters of one output channel to an other
one. The Xover FIR, available on each output Path, are included in this copy tool. The Routing
available on each couple of outputs (1/2, 3/4) is not included in the copy tool.
Default: tool which can be used to bring back the
LPP260A
to the default setup, which is matching the
one got by the Hw reset. All parameters are flatted and the all outputs are in MUTE
User
(password selection): by default (when released by the factory) the password for locking
permanently the
LPP260A
is set as “
000000
”. Using the USER tool, the user can define is own
password of six characters. Just providing at the very beginning the password “000000”. a windows is
entered allowing the user to assign a new password and confirm it.