GAIN WINDOW
This “simple” window is allowing a quick control of the Input and Output Gains, so as the Input and
Output Mutes. More, a complete “one shot” view of the ALL Input and Outputs Meters is given here.
IMPORTANT NOTE
: the
LPP260A
has in internal Algorithm controlling the level coming from the
Processes including gain variations as, Filtering Gains or Simply Level Gains, there where the Gain
coming from the processes themselves can be a positive one. In this case, it is possible, given an input
level close the the max available, to have internal processes overflow. The
LPP260A
inner Clip limiting
Algorithm is detecting the potential or already occurring overflows and is containing them up to a
12dB Headroom, with a process “distortion free” based on level reduction tabled coefficients. When
overflow over 12dB occurring, the Algorithm is containing them with a no distortion free process,
which progressively is increasing the distortion level as more as the overflow containment is
exceeding the +12dBu. The result of this “transparent to the user process”, is a NOT CLIPPED output
signal even with large excess of gaining internal processes and Input levels close to the max accepted
by the unit. The process is active ONLY in case of Overflow occurring; when the signal is not exceeding
with the sum of the Input level and the processes gain, the unit's dynamic, then the process is not
active.