AVS S-SERIES INSTALLATION MANUAL - GEN 2 VER 5
17
Programming features Register 1 continued
Vehicle set up: Close all doors, bonnet & boot, arm & disarm alarm then turn ignition on, off & on.
Feature:
Shock sensor adjustment
Press the
button
this many times:
11
Factory setting:
6
Description:
After pressing the
button 11 times to enter this mode, turn the ignition to off. The
siren should chirp the current sensor setting (factory level of 6). There are 8 levels of
adjustment. Pressing the
button once will increase the sensitivity by one level i.e.
to level 7 if set at factory level. The LED will then flash seven times to confirm the new
level.
Pressing the remote again will increase the sensitivity to level 8 (max). Pressing the
remote again will return the adjustment to level 1 (least sensitive) and so on.
Once you have adjusted the sensitivity level to the desired setting, turn the ignition on
and off again to exit this mode. The siren should chirp the new setting to confirm.
Feature:
Installer mode
Press the
button
this many times:
12
Description:
This mode allows the installer to verify that each trigger of the alarm system is working,
without having to arm and disarm the system each time and setting off the siren.
After pressing the
button 12 times to enter this mode, turn the ignition to off. The
siren will chirp and the indicators will flash to indicate a trigger e.g. push the bonnet
switch, open a door, hit the vehicle. The siren will chirp four times to indicate a shock
sensor pre-warning impact.
Feature:
Past Alarm Trigger memory
Press the
button
this many times:
13
Description:
After pressing the
button 13 times to enter this mode, turn the ignition off. The
system stores the 10 last reasons why the alarm was triggered. This memory cannot be
erased.
1 chirp, 1 flash = voltage drop trigger
2 chirp, 2 flashes = glass break sensor trigger (S5 only)
3 chirp, 3 flashes = shock sensor trigger
4 chirp, 4 flashes = power failure
5 chirp, 5 flashes = ignition trigger
6 chirp, 6 flashes = auxiliary trigger (Tilt sensor on S5)
7 chirp, 7 flashes = door trigger
8 chirp, 8 flashes = bonnet / boot trigger
If two previous alarms were recorded i.e. voltage drop and shock sensor the LED will
flash and the siren will chirp once for voltage drop, then no noise for one second, then
the LED will flash and the siren chirp three times for shock sensor. The last memory
heard is the most recent alarm sector triggered. Turn the ignition on and off to exit this
mode.