background image

AVS S-SERIES INSTALLATION MANUAL - GEN 2 VER 5 

 

15 

 

Changing programmable features 

 

 

The AVS S-Series programming mode is very quick and easy to use. Follow the steps below to change any of the 
programmable features: 

 

1.

 

Find the Register (1 or 2) in which the feature is located. 

 

2.

 

Set  the  vehicle  up  as  described  to  access  the  required  Register.  e.g.  to  access  Register  1  close  all  doors, 
bonnet and boot, arm and disarm alarm then turn ignition on, off and back on. 

 

3.

 

Press  the 

  button  on  the  remote  the  number  of  times  for  the  function  you  wish  to  change.  

e.g. for arm and disarm chirps press the 

 button two times. Each press of the button will be confirmed 

by a flash of the indicators and dash LED and a chirp from the siren if connected. 

 

4.

 

Turn the ignition off. 

 

5.

 

The system will then confirm whether the feature is on or off. If the feature is enabled (turned on) the siren 
will chirp once. If the feature is disabled (turned off) the siren will chirp twice. 

 

Programming features Register 1 

 

Vehicle set up:        Close all doors, bonnet & boot, arm & disarm alarm then turn ignition on, off & on. 

 

Feature: 

Arm and disarm chirp (S5/S4) 

Press the 

 button 

this many times:

 

Factory setting: 

ON 

Description: 

One chirp on arm and two chirps on disarm. 

Feature: 

Door lock on ignition 

Press the 

 button 

this many times:

 

Factory setting: 

OFF 

Description: 

When  this feature is ON, the doors will lock when the ignition is turned on, and unlock 
when the ignition is turned off. 

Feature: 

No door ajar warning 
Use if the car has factory interior light delay 

Press the 

 button 

this many times:

 

Factory setting: 

OFF 

Description: 

When this feature is ON, the door ajar warning feature is removed so the indicators and 
siren  will  not  chirp  for  three  seconds  if  the  door  is  left  open.  It  will  ignore  the  door, 
bonnet/boot & aux circuits for 45 seconds upon arming. 

Feature: 

Perimeter night light 

Press the 

 button 

this many times:

 

Factory setting: 

OFF 

Description: 

When this feature is ON, the indicators will stay on constantly for 20 seconds on disarm, 
or until the ignition is turned on. This allows for illumination around the vehicle at night. 

 

Содержание AVS S Series

Страница 1: ...system includes control equipment including setting and unsetting facilities all sensors warning devices and provisions for immobilization of the vehicle AVS S5 Certification Test Report XF2106 R2 Th...

Страница 2: ...s factory remote Anti hijack modes Courier feature Automatic re arm and re lock 4 5 Additional features Data battery back up siren V2 AVS S5 S4 Intelligent two stage shock sensor AVS S5 S4 Intelligen...

Страница 3: ...remote interface MAP function on off Voltage drop sense override Turbo timer run time On board turbo timer Delayed panic MAP Feature 2 second entry delay Factory remote interface for old OEM Enhanceme...

Страница 4: ...fuse detects an overload it will open to prevent damage to the alarm components Once the overload has been removed the polyfuse will automatically reset If you find a circuit does not work i e central...

Страница 5: ...e remotes LED will flash instead of lighting constantly when a button is pressed Panic car finder Press the button on the remote control for three seconds The indicators will flash and the siren will...

Страница 6: ...timer allows the vehicle to run for 1 2 or 4 minutes after the ignition is switched to off Interface will interface with an external turbo timer to allow the vehicle to run on the turbo timer after th...

Страница 7: ...vironmental shocks caused by aircraft trucks or extreme weather conditions and the impact caused by a thief attempting to break in or other heavy impacts The sensor also auto adjusts During the first...

Страница 8: ...vailable sequence above 2 A new remote can be coded into the system 12 times You can do this by coding the same remote in even if you only have one remote 3 Or the unit can be sent back to Manta Elect...

Страница 9: ...AVS S SERIES INSTALLATION MANUAL GEN 2 VER 5 9 NOTE Unless a remote control is learnt in you will need to repeat the procedure every time you wish to start the car...

Страница 10: ...ater date it is possible to trace the required wires by first un clipping the case Next slide the circuit board out to expose the main connector plug Use the following connector diagram below to trace...

Страница 11: ...with other alarm wires marked with red and white sheathing Green this wire gives a constant 200mA negative output ALARM when the alarm is triggered It can be used to run additional piezo sirens or to...

Страница 12: ...to a timed 15 second negative on arm wire This will allow you to connect this wire via a relay refer Timed Headlight diagram to your headlight circuit so that when the system is armed the headlights w...

Страница 13: ...CDL connection 24 UNLOCK COM Refer to Central Door Lock diagrams for CDL connection IM2A 2 wires and IM2B 2 wires Ignition immobiliser circuit The ignition wire is usually located under the steering c...

Страница 14: ...AVS S SERIES INSTALLATION MANUAL GEN 2 VER 5 14...

Страница 15: ...wice Programming features Register 1 Vehicle set up Close all doors bonnet boot arm disarm alarm then turn ignition on off on Feature Arm and disarm chirp S5 S4 Press the button this many times 2 Fact...

Страница 16: ...cle is safe inside The light stays on for 20 seconds or until the ignition is turned on The dome interior light also comes on automatically when the ignition is turned off enabling the owner to quickl...

Страница 17: ...stem is working without having to arm and disarm the system each time and setting off the siren After pressing the button 12 times to enter this mode turn the ignition to off The siren will chirp and...

Страница 18: ...AVS S SERIES INSTALLATION MANUAL GEN 2 VER 5 18...

Страница 19: ...ne thermo fans cut in automatically or there are other accessories active even when the ignition is turned off e g car phones TO ACTIVATE VOLTAGE DROP TURN FEATURE OFF Feature Turbo timer run time Pre...

Страница 20: ...ncement module to work Note if using this module the alarm will now arm on button and disarm on when using AVS remote Feature Courier Mode Press the button this many times 20 Factory setting OFF Descr...

Страница 21: ...ing OFF Description This feature prevents the accidental system disarming of the system When turned ON it will re arm and re lock the doors if the system is disarmed and a door not opened within 60 se...

Страница 22: ...AVS S SERIES INSTALLATION MANUAL GEN 2 VER 5 22...

Страница 23: ...turned ON the unlock output becomes a 15 second negative pulse instead of 0 5 seconds This feature is for use with vehicles with vacuum central locking Feature Anti Hijack Mode 1 Press the button this...

Страница 24: ...larm will also activate for five minutes after the anti hijack trigger can be turned off via Register 2 Feature 11 Feature Alarm on Anti Hijack trigger Press the button this many times 11 Factory sett...

Страница 25: ...t ensure the cooling fans continue to run when the vehicle is running on the turbo timer you may need to hook up the second ignition wire relay as per next page Note IM2A MUST BE CONNECTED TO 12V MAIN...

Страница 26: ...STALLATION MANUAL GEN 2 VER 5 26 6 Once the desired time duration is selected simply turn the ignition on then off The siren should chirp the new run time setting indicating the turbo timer time durat...

Страница 27: ...l arm the alarm and lock the doors as normal but the immobiliser relays will stay closed until the pre programmed time out If the alarm detects an intrusion the alarm will sound and the system will im...

Страница 28: ...ement the maximum run time allowed for the turbo timer There are four levels each level is indicated by the number of chirps See table below It is very important that the external turbo timer does not...

Страница 29: ...switch to disarm the alarm Inhibit mode is a much more secure upgrade option The table below describes each upgrade wires operation Wire Inhibit mode Enable mode POS1 Positive arm arms the alarm when...

Страница 30: ...gnition on then off and the momentary switch is pressed or pin code is entered Mode 1 In mode 1 the unit will enter anti hijack countdown following the opening of a door when the ignition is on Upon e...

Страница 31: ...n in courier mode the shock AVS S5 S4 glass sensor AVS S5 will be disabled when the engine is running but will arm normally when the ignition is off Note the AUX input remains active in courier mode N...

Страница 32: ...ehicle Connect to lock wire of vehicle 2 Positive pulse CDL system Cut Cut Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Earth Earth Connect to unlock wire of vehicle Connect to lock wire of...

Страница 33: ...stem Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Vehicle s Existing CDL Switch Vehicle s Existing Door Motor Cut Cut Earth Connect to relay side of control wire Connect to Unlock COM 5 Sin...

Страница 34: ...AVS S SERIES INSTALLATION MANUAL GEN 2 VER 5 34 Timed Headlight diagram Optional Siren diagrams seepage18 for Data Siren...

Страница 35: ...e these signals and will put out a basic low current negative Note If you want to use the alarm boot pop or alarm panic channel be aware that Ch 2 on the RXPRO or RCX 4 will also activate Parts requir...

Страница 36: ...fuse may take several minutes before resetting Wait and re test Turbo timer problems No engine shut down on boot button Engine only runs for 10 seconds Turn ON Register 1 Feature 17 Register 1 Feature...

Отзывы: