Section 4
Maintenance
Part Number 000001196 3/08
4-5
CLEANING PROCEDURE
Ice machines that are heavily scaled or have not been cleaned on a regular basis will need to run the Heavily Scaled
Cleaning Procedure before this one. Failure to do so may result in binding of the auger as the lime scale releases
from the auger and evaporator barrel.
Ice machine cleaner is used to remove lime scale or other mineral deposits. It is not used to remove algae or slime.
Refer to the “Sanitizing Procedure” for removal of algae and slime.
Step 1
Remove panels and set the ICE/OFF/CLEAN
toggle switch to the OFF position
Step 2
Turn off the water supply to the ice machine.
Step 3
Remove all ice from the bin.
Step 4
Place ICE/OFF/CLEAN toggle switch in the
CLEAN position. The dump valve will open and drain the
water from the evaporator and reservoir.
Step 5
Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in the
OFF position.
Step 6
Refer to chart and premix the correct solution of
cleaner and cool water for your model ice machine.
Step 7
Remove the top cover from the ice chute and
pour the cleaner/water solution into the evaporator. Add
the entire amount of premixed solution (excess solution
will exit through the overflow tube in the water
reservoir).
Step 8
Replace the ice chute cover and allow the ice
machine to stand for 30 minutes.
Step 9
Turn on the water supply to the ice machine.
Step 10
Move the toggle switch to the ICE position.
The compressor will energize and produce ice with the
cleaning solution.
Step 11
The ice machine will freeze and discharge the
cleaning solution into the bin. Allow the cycle to run for
15 minutes.
Step 12
Place the toggle switch in the OFF position
and refer to sanitizing procedure.
NOTE: Discard all ice produced during the cleaning
process. Cleaning and sanitizing must be performed on
adjacent surface areas not contacted by the water
distribution system. Refer to Removal of Parts for
Cleaning/Sanitizing (Page 4-7) - Disassemble, clean and
sanitize the ice machine a minimum of once every six
months.
!
Caution
Use only Manitowoc approved Ice Machine Cleaner
part number 000000084. It is a violation of Federal
law to use these solutions in a manner inconsistent
with their labeling. Read and understand all labels
printed on bottles before use.
Model
Amount of
Cleaner
Part Number
000000084
Amount of Water
SF0400 SN0450
2 ounces (60 ml)
32 ounces (1 liter)
SF0600 SN0650
3 ounces (90 ml)
32 ounces (1 liter)
SF0900 SN0950
4 ounces (120 ml
32 ounces (1 liter)
SF1200 SN1250
8 ounces (235 ml)
64 ounces (2 liter)
Содержание RFC0985
Страница 12: ...General Information Section 1 1 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...Installation Instructions Section 2 2 30 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...Maintenance Section 4 4 14 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Section 5 Before Calling for Service Part Number 000001196 3 08 5 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Before Calling for Service Section 5 5 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 67: ......