Installation Instructions
Section 2
2-14
Part Number 000001196 3/08
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Typical Water Supply Drain Installation
!
Caution
Plumbing must conform to national, state and local
codes.
Location
Water Temperature
Water Pressure
Ice Machine Fitting
Tubing Size Up to Ice
Machine Fitting
Ice Making
Water Inlet
45°F (7°C) Min.
90°F (32°C) Max.
20 psi (1.4 bar) Min.
80 psi (5.5 bar) Max.
3/8" Female
Pipe Thread
3/8" (9.5 mm) minimum
inside diameter
Condenser
Water Inlet
33°F (0.6°C) Min.
90°F (32°C) Max.
20 psi (1.4 bar) Min.
150 psi (10.3 bar) Max.
1/2" Female
Pipe Thread
1/2" (12.7 mm) minimum
inside diameter
Condenser
Water Drain
---
---
1/2" Female
Pipe Thread
1/2" (12.7 mm) minimum
inside diameter
Bin Drain
---
---
3/4" Female
Pipe Thread
3/4" (19.0 mm) minimum
inside diameter
SV3142
ELECTRICAL ENTRANCE
18” (46 CM) VENT TUBE
1/2” (1.3 CM) MIN
DRAIN ID
1/2” DRAIN CONNECTION
PLASTIC FITTING ON OPPOSITE
SIDE DO NOT APPLY HEAT
OPEN, TRAPPED AND
VENTED DRAIN
DO NOT TRAP DRAIN LINE,
LEAVE AIR GAP BETWEEN
DRAIN TUBE AND DRAIN
3/8” FPT ICE MAKING WATER INLET FITTING,
PLASTIC FITTING ON OPPOSITE SIDE DO NOT
APPLY HEAT
1/2” FPT CONDENSER WATER DRAIN
(WATER COOLED UNITS ONLY)
3/8” FPT CONDENSER WATER INLET
(WATER COOLED UNITS ONLY
1/2” CPVC SOCKET
AUXILLARY BASE
DRAIN
INSTALL BRACKETS AND
SECURE ICE MACHINE TO
DISPENSER
Содержание RFC0985
Страница 12: ...General Information Section 1 1 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...Installation Instructions Section 2 2 30 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...Maintenance Section 4 4 14 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Section 5 Before Calling for Service Part Number 000001196 3 08 5 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Before Calling for Service Section 5 5 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 67: ......