Section 5
Before Calling for Service
Part Number 000001196 3/08
5-3
SafeGuard Modes
NO WATER
During the Freeze cycle if the water sensing switch
opens or remains open for more than 20 continuous
seconds,
1. The ice machine will de-energize the compressor
and gear motor immediately
2. Continuously flash the control board water OK light
3. Initiate a 5 minute Standby Mode
After the 5 minute standby the ice machine will check the
status of the water level sensor.
WATER LEVEL SENSOR CLOSED:
The ice machine will initiate a startup sequence.
WATER LEVEL SENSOR OPEN:
The ice machine will wait for the water level sensor to
close.
INDICATOR LIGHT
Before 48 hours have elapsed:
After a Standby Mode has been initiated the water level
light will flash anytime the toggle switch is placed in the
OFF position.
After 48 hours have elapsed:
The SafeGuard will be automatically erased from
memory and the water level will not flash.
No Water SafeGuard Checklist
Possible Problem List
Corrective Action List
No water
Restore water supply.
Water float valve screen blocked
Clean screen.
Water float valve improperly adjusted
Adjust valve (see Water level check).
Dump valve leaking
Repair or replace dump valve.
Water sensing switch disconnected or removed
Connect or correctly position sensor
Float reservoir cover is removed
Install reservoir cover
Содержание RFC0985
Страница 12: ...General Information Section 1 1 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...Installation Instructions Section 2 2 30 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...Maintenance Section 4 4 14 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Section 5 Before Calling for Service Part Number 000001196 3 08 5 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Before Calling for Service Section 5 5 6 Part Number 000001196 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 67: ......