Operation
Section 3
3-4
Part Number 000001196 3/08
Control Board Features
FLUSH CYCLE
After the ice machine has completed 50 hours of run
time a flush sequence will start. This cycle will drain and
refill the evaporator to remove minerals that have settled
to the bottom of the evaporator. The flush sequence
lasts approximately 21 minutes, after which the ice
machine will reset the 50 hour counter and automatically
start ice making again.
POWER INTERRUPTION DELAY
If power is disconnected the ice machine stops. When
power is reapplied a 5 minute delay is initiated.
SafeGuards
The ice machine control board has safety features to
protect the ice machine from severe failures. The ice
machine will stop when conditions arise that would
cause major component failure. Refer to section 5 for
details.