114
Part Number 000014797 Rev02 05/18
Procedure
Step
1. Determine the ice machine operating conditions.
Example:
Air temperature entering condenser: 90°F/32.2°C
Air temperature around ice machine: 80°F/26.7°C
Water temperature entering water fill valve: 70°F/21.1°C
2A. Refer to “Cycle Time” and “Operating Pressure” charts for ice
machine model being checked. Using operating conditions from
Step 1, determine published freeze cycle time and published
freeze cycle suction pressure.
Example:
Published freeze cycle time: 14.8 - 15.9 minutes
Published freeze cycle suction pressure: 65 - 26 psig
2B. Compare the published freeze cycle time and published
freeze cycle suction pressure. Develop a chart.
Example:
Published Freeze Cycle Time (minutes)
1 2 4 7 10 12 14
| | | | | | |
65 55 47 39 34 30 26
Published Freeze Cycle Suction Pressure (psig)
In the example, the proper suction pressure should be
approximately 39 psig at 7 minutes; 30 psig at 12 minutes; etc.
3. Perform an actual suction pressure check at the beginning,
middle and end of the freeze cycle. Note the times at which the
readings are taken.
Example:
Manifold gauge set was connected to the example ice machine
and suction pressure readings taken as follows: ________ PSIG
Beginning of freeze cycle: 79 (at 1 min.)
Middle of freeze cycle: 48 (at 7 min.)
End of freeze cycle: 40 (at 14 min.)
4. Compare the actual freeze cycle suction pressure (Step 3)
to the published freeze cycle time and pressure comparison
(Step 2B). Determine if the suction pressure is high, low or
acceptable.
Example:
In this example, the suction pressure is considered high
throughout the freeze cycle. It should have been:
Approximately 65 psig (at 1 minute) – not 79
Approximately 39 psig (at 7 minutes) – not 48
Approximately 26 psig (at 14 minutes) – not 40
Содержание NEO UD0140A
Страница 2: ......
Страница 20: ...20 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 182: ...182 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 215: ...Part Number 000014797 Rev02 05 18 215 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING Using Pinch Off Tool ...
Страница 252: ...252 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE065 1 2 3 4 5 6 ...
Страница 254: ...254 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE080 1 2 3 4 5 6 7 8 9 10 ...
Страница 258: ...258 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 259: ......