Part Number 000014797 Rev02 05/18
173
Suction Temperature High Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
Discharge Pressure
• Discharge temperature is too high, and is affecting
suction temperature, refer to “Discharge Line
Temperature High Checklist” on page 171.
Improper Refrigerant Charge
• Overcharged
• Wrong type of refrigerant
• Non-condensible in system
Other
• Non-Manitowoc components in system
• Harvest valve leaking
• TXV flooding (check bulb mounting)
• Defective compressor