79
Beermaster Low CO
2
Alarm Kit
The following instructions cover the installation
procedures for installing the Beermaster Low CO
2
Alarm Kit. Installation should be performed by qualified
personnel.
INSTALLING THE LOW CO
2
ALARM KIT
1. Turn OFF CO
2
at the CO
2
tank and bleed all
pressure from line.
2. Locate the 1/4" x 1/4" x 1/4" stainless steel tee
supplied with the alarm kit. Install this tee in the
CO
2
pressure line between the high pressure
regulator and the medium pressure regulator. Use
two tab clamps per connection (refer to the figure
below).
NOTE: If beer system is equipped with an blender, tee
must be installed upstream of the blender.
3. Locate the alarm box and transformer supplied
with kit. Mount the alarm box in a convenient
location near the CO
2
pressure switch. Place
slide switch on face of alarm box to “Beeper off”
position.
Beermaster
Glycol Chiller
Pump Assembly
Air
Compressor
Mounting
Channel
Support
Stand