Published 03-21-2021, Control # 264-01
4-5
MLC150-1 SERVICE/MAINTENANCE MANUAL
BOOM
4
AUTOMATIC BOOM STOP ASSEMBLY
The automatic boom stop assembly (1, View A and C) is
mounted on the right-front inboard side of the rotating bed.
The assembly consists of one or two limit switches (10 and
11, View A) depending on how the crane is equipped. The
limit switches stop the boom at the following maximum
angles:
•
Limit switch (10): 82° for Boom only or Boom with Fixed
Jib
•
Limit switch (11): 88.5° for Boom with Luffing Jib
The limit switch angles are greater than the maximum
Capacity Chart angles in order to reach to the minimum
c h a r t r a d i i w i th l oa d o n th e h oo k a n d t he b oo m
deflected.
When the boom is below the maximum angle, the
corresponding limit switch is closed, providing a continuous
28 VDC signal to the crane’s control system.
When the boom is raised to the maximum angle, the actuator
(2, View A) depresses the actuator rod (5) and the actuator
rod trips the corresponding limit switch open. Voltage drops
to 0 VDC, signaling the crane’s control system to stop the
boom hoist and apply its brake.
When the maximum boom angle is reached,
the fault alarm comes on and the boom
maximum up icon appears in the Alerts Bar
of the Main Display Working Screen.
To correct the fault once it is activated, lower the boom. The
fault cannot be bypassed.
Automatic Boom Stop Maintenance
At least once a week, check that the automatic boom stop
stops the boom at corresponding angle: 82° or 88.5
depending on how the crane is equipped. If it doesn’t,
replace any worn or damaged parts and/or adjust the
automatic boom stop.
Automatic Boom Stop Adjustment —
without Luffing Jib
The limit switch (10) for the automatic boom stop with boom
only or boom with fixed jib was set at the factory and should
not require periodic adjustment. Adjustment is necessary
when:
•
Parts are replaced
•
The wrong angle is displayed in the RCL/RCI
The following instructions assume that the RCL/RCI is
installed and properly calibrated.
During the following procedure, the boom angle is monitored
on the Working Screen of the RCL/RCI Display (
) and on a smart level (4, View B,
Unless other wise indicated refer to View A,
for
the following procedure.
1.
Park the crane on a firm level surface or level the crane
by blocking under the crawlers.
2.
Slowly raise the boom while monitoring the boom angle
on the RCL/RCI working screen.
3.
The boom must stop at 82°.
4.
If the boom does not stop at the specified angle, proceed
as follows:
a.
Remove the cover from the boom stop assembly.
b.
Lower the boom to approximately 80°.
c.
Loosen the jam nuts (7), the adjusting screws (6),
and the mounting screws (8).
d.
Slide the limit switch (10) rearward approximately
52,4 mm (1 in).
e.
Raise the boom to 82° and verify the boom angle
with an accurate smart level (4, View B) placed on
the boom butt bottom chord. The smart level angle
should read angle X1.
f.
Slide the limit switch (10) forward in the mounting
slots until the roller (9) is contacting the sloped edge
of the actuator rod (5).
g.
Turn the rear adjusting screw (6) clockwise to move
the limit switch forward in the mounting slots
only
enough to click the limit switch open and stop
.
h.
Securely tighten the mounting screws (8), both
adjusting screws (6) against the limit switch (10),
and the jam nuts (7).
i.
Boom down and then boom back up. The boom
must stop at the 82° maximum boom angle.
j.
If necessary, loosen the jam nuts (7) and mounting
screws (8) and fine tune the adjustment using the
adjusting screws (6).
k.
When done, securely tighten the mounting screws
(8), both adjusting screws (6) against the limit switch
(10), and the jam nuts (7).
l.
Reinstall the cover on the boom stop assembly.
WARNING
Falling Attachment Hazard!
Do not operate the crane unless the automatic boom stop
limit switches are properly adjusted and operational. Do
not adjust the maximum operating angle higher than
specified. The boom could be pulled over backward or
collapse, causing death or serious injury.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...