![Manitowoc MLC150-1 Скачать руководство пользователя страница 197](http://html.mh-extra.com/html/manitowoc/mlc150-1/mlc150-1_service-maintenance-manual_701242197.webp)
Manitowoc
Published 03-21-2021, Control # 264-01
10-1
MLC150-1 SERVICE/MAINTENANCE MANUAL
ACCESSORIES
10
SECTION 10
ACCESSORIES
This section provides operational information for the crane’s
accessory hydraulic systems.
Additional component information for this system can be
found in the following sections of this Service Manual:
•
Section 2: Hydraulics
•
Section 3: Electrical
NOTE:
In the following instructions,
CCS
stands for
C
rane
C
ontrol
S
ystem.
GANTRY CYLINDERS OPERATION
Gantry Cylinders Overview
The gantry cylinders are controlled by a switch either on the
remote control or on the right side cab console.
The system consists of the OLB pump, a 2-position,
proportional solenoid-operated accessory enable control
valve, a 3-position, solenoid-operated control valve, and two
double-acting hydraulic cylinders with holding valves.
The setup remote control communicates with the gantry
cylinder solenoid valves via the CCS.
The switch on the cab console communicates with the gantry
cylinder solenoid valves via the CCS.
To activate the setup remote control, it must be turned in
crane’s main display. See the Main Display Operation
Manual provided with the crane.
To activate the gantry cylinders switch on the cab console,
the Boom Butt Configuration must be selected in the RCL/
RCI Display. See the RCL/RCI Operation Manual supplied
with the crane.
Both gantry cylinder switches are 3-position momentary
switches that are spring returned to the off position when
released.
Neutral
When there is no command from either gantry cylinders
switch, the following occurs:
•
The solenoid on the accessory enable valve is
deenergized and a spring shifts the valve to block pump
A flow to the high pressure accessory valve bank.
•
The solenoids on the gantry cylinders control valve are
deenergized and springs shift the valve to the neutral
position.
•
The gantry cylinders are held in their last position by the
holding valve on each cylinder.
Retract
When a retract command is sent by either gantry cylinders
switch, the following occurs:
•
The proportional solenoid on the accessory enable valve
is energized by a PWM (pulse width modulation) signal
from the CCS to adjust the flow rate of oil to the high
pressure accessory valve bank.
•
At the same time, the retract solenoid on the gantry
cylinders control valve is energized by 24 VDC from the
CCS.
•
The energized solenoid shifts the valve spool to the
position that routes hydraulic oil to the rod end of the
gantry cylinders.
•
Pressure from the rod ends of the cylinders pilots open
the load holding valves allowing the oil from the barrel
end of the cylinders to flow back to tank via the high
pressure accessory valve.
•
The cylinder rods retract to lower the gantry.
Load Holding
If hydraulic pressure is lost for any reason, the holding valves
close and the check valve traps the oil in both ends of each
cylinder, preventing the cylinders from extending or
retracting.
Extend
When an extend command is sent by either gantry cylinders
switch, the following occurs:
•
The proportional solenoid on the accessory enable valve
is energized by a PWM signal from the control system to
adjust the flow rate of oil to the high pressure accessory
valve bank.
•
At the same time, the extend solenoid on the gantry
cylinders control valve is energized by 24 VDC from the
CCS.
•
The energized solenoid shifts the valve spool to the
position that routes hydraulic oil to the barrel end of the
gantry cylinders.
•
The oil flows over the load holding check valves to the
barrel end of the cylinders and the cylinders extend to
raise the gantry.
•
The hydraulic oil in the rod end of the cylinders flows
back to tank via the high pressure accessory valve.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...