Table 3-10. IOLC31 Test Voltages
Pin
Net
Function
Voltages
P1-1
GND
Ground (from ground stud on rotating bed)
0 VDC
P1-2
KL15
Control Module Ignition Power (from engine RUN switch)
0 VDC Open, 24 VDC Closed
P1-3
ID01
Drum 1 Flange Encoder and Minimum Bail Limit Switch
0 VDC Open, 24 VDC Closed
P1-4
ID02
Drum 2 Minimum Bail Limit Switch
0 VDC Open, 24 VDC Closed
P1-5
OPH6A18
Drum 3 Valve A
P1-6
OPH6A19
Drum 3 Valve B
P1-7
OPH6A20
A/C Condenser
0 or 24 VDC
P1-8
OPH6A21
High Pressure Acc Enable
P1-11
8C23 (+UB) Battery Power for Control Module Outputs (from CB23)
24 VDC
P1-12
8C24 (+UE) Control Module Battery Power (from K5)
24 VDC
P1-13
ID03
Drum 1 Flange Encoder and Minimum Bail Limit Switch
0 VDC Open, 24 VDC Closed
P1-15
ID05
Boom Up Limit
P1-16
ID06
Block Up Limits (all)
0 VDC Open, 24 VDC Closed
P1-17
IDF15
Drum 1 Motor Speed Sensor
6% (low) to 70% (high) of 8.5 VDC
P1-20
8C36 (+UB) Battery Power for Control Module Outputs (from CB23)
24 VDC
P1-26
IDF16
Drum 1 Motor Speed Sensor
6% (low) to 70% (high) of 8.5 VDC
P2-3
ID14
Boom Up Limit
P2-4
IACV18
Drum 2 Motor PSI
4 to 20 mA
P2-5
ODH3A02
Drum 2 and 3 Motor PSI
0 VDC
Off, 24 VDC On
P2-6
ODH3A04
Alarm Switch Swing and Travel Limit
0 VDC
Off, 24 VDC On
P2-7
ODH3A07
Pump 1 and Pump 2 Pressure
P2-10
OPH3A15
25VDC Drum 2 Sensors
P2-11
8C24 (+UB) Battery Power for Control Module Outputs (from CB24)
24 VDC
P2-13
IACV19
Swing Left PSI
4 to 20 mA
P2-14
IACV20
Swing Right PSI
4 to 20 mA
P2-15
ODH3A01
Drum 1 Minimum Bail PSI, Drum 1 Motor Speed
24 VDC
P2-16
ODH3A06
Boom Angle Sensor
24 VDC
P2-17
OPH3A09
28VDC Power to Boom
P2-18
OPH3A14
Drum 1 Motor Control
0 to 24 VDC
P2-20
8C23 (+UB) Battery Power for Control Module Outputs (from CB24)
24 VDC
P2-22
IACV21
Pump 1 Pressure
P2-23
IACV22
Pump 2 Pressure
P2-24
OPH3A03
28VDC Power Luffing Jib Up Limit
P2-25
ODH3A05
Alarm
0 VDC
Off, 24 VDC On
P2-26
ODH3A08
Boom Up Limit
P2-27
ODH3A11
Load Link
P2-28
ODH3A13
Left and Right Swing PSI
0 VDC
Off, 24 VDC On
P2-29
OPH3A16
Drum 3 Motor Control
0 to 24 VDC
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...