DRUM 3 MINIMUM BAIL LIMIT
Optionally, Drum 3 has a combination minimum bail limit and
pressure roller.
During normal operation with more than three to four wraps
of wire rope on the first layer of the drum, springs hold the
roller (2, View D) firmly against the wire rope to assist in
proper spooling.
When there are three to four wraps of wire rope on the first
layer of the drum, the small diameter end of the roller (2,
View D) contacts the drum. This action activates the bail limit
fault by rotating the actuator (3, View B) down against the
limit switch (4, View C).
When the fault is activated, the drum stops
lowering and the fault icon appears in the fault
bar of the Main Display Working Screen.
• The drum can be operated in the hoist
direction after the limit is contacted.
• The limit can only be bypassed by disconnecting the
electric cable (5, View C) from the electric cable (6) and
connecting the supplied shorting plug (7) to the electric
cable (6).
Limit Switch Adjustment
1.
Pay out the wire rope from Drum 3 until there are three
to four wraps of rope on the first layer of the drum.
2.
If necessary, loosen the lock nut (3A, View B) and turn
the adjusting screw (3B):
•
OUT to stop the drum SOONER
•
IN to stop the drum LATER
3.
Operate the drum to make sure it stops with three to four
wraps of wire rope on the first layer of the drum.
4.
Readjust the limit switch as needed.
WARNING
Falling Load Hazard!
When lowering a load below the minimum bail limit, do so
slowly with extreme caution. Do not lower the load to the
point where less than three full wraps of wire rope are on
the drum. The wire rope could be pulled out of the drum,
allowing the load to fall.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...