Replacing Breather
NOTE:
The breather is accessible through the door in the
top of the left enclosure.
1.
Check the breather service indicator (4) daily or every 8
hours of engine operation, whichever occurs first.
2.
Replace the breather (3) when the red flag in the service
indicator (4) rises to the top and locks in place.
When locked in place, the red flag will remain out after
the engine is stopped (pressure exhausted).
3.
Stop the engine.
4.
Vent the hydraulic tank using either of the vent valves (1
or 2).
Take precautions to prevent being burned by
hot oil
.
5.
Unscrew the breather (3) and dispose of it according to
local environmental regulations.
The breather is not
serviceable
.
6.
Remove any shipping material from the new breather.
7.
Apply pipe tread sealant to the breather threads and
securely attach the breather to the indicator coupling (5).
8.
Push in the reset button (6) in the end of the service
indicator (4).
Replacing Hydraulic Filters
WARNING
Burn Hazard!
The oil in the hydraulic tank may be under pressure and
extremely hot. Hot oil can escape when servicing
components.
•
Allow the hydraulic system to cool before replacing
the breather or the hydraulic filters.
•
Before opening the tank, relieve any pressure from
the tank using either vent valve (8 or 9,
).
Item
Description
1
Vent Valve (requires mating coupler)
2
Schrader Valve
3
Breather
4
Service Indicator
5
Indicator Coupling
6
Reset Button
FIGURE 2-19
WARNING
Burn Hazard!
The oil in the hydraulic tank may be under pressure and
extremely hot. Hot oil can escape when servicing
components.
•
Allow the hydraulic system to cool before replacing
the breather or the hydraulic filters.
•
Before opening the tank, relieve any pressure from
the tank using either vent valve (8 or 9,
).
CAUTION
Avoid Hydraulic System Damage!
Original equipment manufacturers’ filter elements,
available from the Manitowoc Crane Care Lattice Team,
must be used on this crane. Substituting with any other
brand or type of filter element is not allowed.
Non-OEM filter elements may collapse under pressure.
This will allow unfiltered oil to be drawn into the hydraulic
system. Pumps, motors, and valves can be destroyed.
Manitowoc Cranes will reject warranty claims for
damaged hydraulic components if proper hydraulic filter
elements are not used.
•
Do not attempt to clean or reuse elements.
•
Do not operate the crane without filter elements
installed.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...