![Manitowoc MLC150-1 Скачать руководство пользователя страница 167](http://html.mh-extra.com/html/manitowoc/mlc150-1/mlc150-1_service-maintenance-manual_701242167.webp)
Manitowoc
Published 03-21-2021, Control # 264-01
7-7
MLC150-1 SERVICE/MAINTENANCE MANUAL
POWER TRAIN
7
There will be some initial resistance, similar to breaking
the seal on a jar. Using the handle (7A) on each filter,
move the end of the filter back and forth to break the
seal.
4.
If required, remove the secondary filter (8) by pulling on
the tabs (8A). Take care to avoid dislodging dust from
the filter.
NOTE:
Replace the secondary filter (8)
every third time
the primary filters (7) are replaced.
5.
Do not clean or reuse the filters
. Dispose of them
according to local environmental regulations.
6.
Using a clean damp cloth, wipe clean the inside of the
cover, the sealing surfaces, and the inside of the air
cleaner housing. These areas must be clean and free of
grease and loose contaminants.
7.
Inspect the new filters, especially the sealing areas.
Never install damaged filters
.
The filters have O-rings that provide an air-tight seal.
8.
If removed, carefully install the new secondary filter (8) –
O-ring side first – with the plastic rings and gently push it
into the back of the housing. Apply pressure to all four
corners to make sure the filter is completely secure in
the housing.
9.
Carefully install the new primary filters (7) – O-ring side
first – using the handles. Make sure all surfaces are
sealed inside the housing.
10.
Make sure the seal is in place and install the cover (6)
with the clips (5). The cover should go on without extra
force.
Never use the clips on the cover to force the filters into
the air cleaner. It is tempting to assume that the cover
will do the job of sealing the filters, but it will not. Using
the cover and clips to push the filters into the housing
could damage the housing and will void the warranty.
11.
Push the reset button (1B) on the service indicator (1).
FIGURE 7-6
Item Description
1
Service Indicator
1a
Indicator Window
1b
Reset Button
2
Air Intake Housing with Seals
3
Pre-Cleaner (not serviceable)
4
Air Cleaner Housing
5
Clip (Qty 4)
6
Cover
7
Primary Filter (Qty 2)
7A
Handle
8
Secondary Filter
8A
Plastic Rings
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...