![Manitowoc 2250 MAX-ER 2000 Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/manitowoc/2250-max-er-2000/2250-max-er-2000_operators-manual_701156092.webp)
Reference
Only
SET-UP AND INSTALLATION
2250 MAX-ER 2000 OPERATOR’S MANUAL
4-12
Published 01-08-13, Control # 049-05
Install Intermediate Suspension Links
See Figure 4-5 for following procedure.
Perform following steps only for #79-44 boom lengths that
require intermediate suspension.
Intermediate suspension is
required for boom lengths of 320 ft (98 m) – 400 ft (122 m).
1.
Unpin and remove standard mast stop (21, View M1)
from both sides of mast butt (store for future use).
2.
Install and pin intermediate suspension mast stop (22,
View M2) to both sides of mast butt.
3.
Pin both mast stops (22) to brackets (23).
4.
Pin suspension links (25, View M2) to mast stops (22).
Pendant pin holes in end of links must face mast
top.
CAUTION
Boom Damage!
Install intermediate suspension, if required, before raising
or lowering boom.