Reference
Only
Manitowoc
Published 01-08-13, Control # 049-05
4-73
2250 MAX-ER 2000 OPERATOR’S MANUAL
SET-UP AND INSTALLATION
4
Anchoring Wire Rope to Drum
See Figure 4-38 for following procedure.
Use the correct wedge part number for the size of wire rope
being used; see parts drawing for the boom hoist drums or
for the load drum shaft to obtain the correct part number.
1.
Assemble wire rope and wedge to drum socket.
2.
Tighten wedge, rapping back of wedge with a brass drift
pin and hammer.
Winding Wire Rope onto Drum
See Drum and Lagging Chart in Capacity Chart Manual for
correct size of drum laggings, if used.
See Wire Rope Specifications Chart in Capacity Chart
Manual for correct type, size, and amount of wire rope to be
installed on load drums.
See Boom Rigging Drawing at end of this section for correct
type, size, and amount of wire rope to be installed on boom
hoist drums.
1.
Carefully inspect drums and all rope guides, rollers, and
sheaves for defects that can cause wire rope to wear or
be cut. If defects cannot be fixed, replace faulty parts.
FIGURE 4-37
Place free end of seizing wire in valley between two stands.
Then wind seizing wire over free end as shown. Finally, twist
and pull two ends of seizing wire together until seizing is tight.
View A
A925
Rope Diameter 1 in (26 mm) and Larger
View B Rope Diameter Smaller than 1in (26 mm)
Wind seizing wire around wire rope as shown. Then twist two ends
of seizing wire together at center of seizing. Alternately twist and pull
ends until seizing is tight.
Wire Rope Type
Seizings
Required
Preformed
1
Non-preformed
7/8 in (22 mm) Diameter or Smaller
2
Non-preformed
1 in (26 mm) Diameter or Larger
3
WARNING!
Falling Load Hazard!
Wire rope can be pulled out of drum if following steps are
not taken.
•
Install straight wedge so corrugated side is against
wire rope.
•
Install wedge so end of wire rope extends past end of
wedge, but not out of drum socket.
•
Make sure seizing is not under wedge. Remove
seizing if it interferes with assembly.
FIGURE 4-38
Hole in
Drum Flange
Straight Wedge
Inside Drum
Straight Wedge
Outside Drum
Don’t Allow End of Wire
Rope to Extend Out of
Socket Opening
Seizing
Seizing
Wire
Rope
Wire
Rope
Содержание 2250 MAX-ER 2000
Страница 1: ...R e f e r e n c e O n l y MAX ER 2000 Operator Manual Manitowoc 2250 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y ...
Страница 56: ...R e f e r e n c e O n l y 2250 MAX ER 2000 OPERATOR S MANUAL 3 ii Published 01 08 13 Control 049 05 ...
Страница 195: ...R e f e r e n c e O n l y ...
Страница 196: ...R e f e r e n c e O n l y ...