86
03/05
SPIDER MAX 500
B
Connect the testing wiring only to the system
connector.
Do not connect to the central unit.
Disconnect the connection across the rpm/speed
sensor and the system.
Measure the sensor resistance by connecting the
multimeter across the + and – terminals.
Rpm/speed sensor resistance = 680
Ω
Ω
Ω
Ω
Ω
± 15%.
Make sure that the pole and shielding are insulated
from the ground. S - + = infinitive (>1M
Ω
).
Replace the rpm sensor.
F. 60
F. 61
F. 62