3
ENGLISH (Original instructions)
Explanation of general view
1-1. Switch trigger
1-2. Lock button
2-1. Switch trigger
2-2. Speed control screw
2-3. Higher
2-4. Lower
2-5. Lock button
4-1. Nozzle
4-2. Blower outlet
4-3. Pin
5-1. Dust bag
5-2. Blower outlet
5-3. Nozzle
5-4. Suction inlet
6-1. Fastener
7-1. Limit mark
8-1. Brush holder cap
8-2. Screwdriver
SPECIFICATIONS
Model UB1102
UB1103
Air pressure
5.7 kPa
0 - 5.7 kPa
Capacities
Max. air volume
4.1 m
3
/min
0 - 4.1 m
3
/min
No load speed
16,000 min
-1
0 - 16,000 min
-1
Overall length
479 mm
479 mm
Net weight
2.0 kg
2.0 kg
Safety class
/II
/II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
ENE018-1
Intended use
The tool is intended for blowing dust.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENG905-1
Noise
The typical A-weighted noise level determined
according to EN60745:
Sound pressure level (L
pA
) : 83 dB (A)
Sound power level (L
WA
) : 94 dB (A)
Uncertainty (K) : 3 dB (A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN60745:
Work mode : operation without load
Vibration emission (a
h
) : 2.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
ENG901-1
•
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
•
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
•
The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
•
Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).
ENH101-18
For European countries only
EC Declaration of Conformity
Makita declares that the following Machine(s):
Designation of Machine:
Blower
Model No./ Type: UB1102, UB1103
Conforms to the following European Directives:
2006/42/EC
They are manufactured in accordance with the following
standard or standardized documents:
EN60745
Содержание UB1102
Страница 14: ...14 3 4 5 6 7 8 Makita Makita Makita Makita 150...
Страница 20: ...20 3 4 5 6 7 8 Makita Makita Makita Makita...
Страница 26: ...26 4 5 6 7 8 Makita Makita Makita Makita...
Страница 29: ...29 UB1102 1 UB1103 2 3 4 5 6 7...
Страница 30: ...30 8 Makita Makita Makita Makita...
Страница 32: ...32 1 8 2014 000331 Makita Jan Baptist Vinkstraat 2 3070 GEA010 1 ENB017 2 1 2 3 4 5 6 7 8 UB1102 1 UB1103 2...
Страница 33: ...33 3 4 5 6 7 8...
Страница 34: ...34...
Страница 35: ...35...
Страница 36: ...36 www makita com Makita Jan Baptist Vinkstraat 2 3070 Belgium Makita Corporation Anjo Aichi Japan 885262A960...