Majestic MARQ36IN-B, MARQ42IN-B Installation Manual • 2614-980 Rev. D • 4/19
50
D. Decorative Barrier Front Dimensions for
Finishing
A decorative barrier front is required for this appliance.
Only decorative barrier fronts certified for use with this
appliance model may be used. Contact your dealer for
a list of decorative barrier fronts that may be used. Once
you have determined what kind of decorative barrier front
and finishing material is going to be used on the fireplace,
you may use the table below which shows the decorative
barrier front models and the finishing material thickness
allowed. For an inside fit there is an available template to
ensure that proper decorative barrier front clearances are
maintained with finishing material with thickness greater
than 1 inch.
A
B
COMBUSTIBLE MATERIAL
Figure 10.11 Inside Fit Decorative Barrier Fronts
The decorative barrier fronts approved for use with this
appliance have been designed to be installed by two
methods: Overlap Fit or Inside Fit. Before beginning the
installation, it is important to determine with method will
be used.
Overlap Fit Method:
These decorative barrier fronts
have been designed to be installed over finishing mate
-
rial up to one inch thick.
Inside Fit Method:
These decorative barrier fronts may
be recessed into non-combustible finishing material up to
10 inches thick.
NOTICE:
Proper clearances from the fireplace opening
to any finishing material thicker than 1 inch MUST be
maintained.
NOTE:
Finishing templates are included with this product.
See Section 10.B.
DIMENSIONS
A
3/4 IN.
B
1-1/4 IN.
Approved Decorative Barrier Fronts: FSMQ36,
FSMQ42