background image

43

Majestic  MARQ36IN-B, MARQ42IN-B Installation Manual  •  2614-980 Rev. D  •  4/19

Gas Information 

A.  Fuel Conversion

•  Make sure the appliance is compatible with available gas 

types.

• Conversions must be made by a qualified service 

technician using Hearth & Home Technologies specified 

and approved parts.

B.  Gas Pressure

C.  Gas Connection

 • Refer to Reference Section 3 for location of gas line 

access in appliance.

•  Gas line may be run through knockout(s) provided.

•  The gap between supply piping and gas access hole 

may be sealed with caulk or aluminum foil tape with a 

minimum of 300 ºF continuous exposure rating or stuffed 

with non-combustible, unfaced insulation to prevent cold 

air infiltration.

•  Ensure that gas line does not come in contact with outer 

wrap of the appliance. Follow local codes.

•  Pipe incoming gas line into valve compartment.
•  Connect incoming gas line to the 1/2 in. (13 mm) NPT 

connection on manual shutoff valve.

WARNING! Risk of Fire or Explosion! 

Support control 

when attaching pipe to prevent bending gas line.

WARNING!  Risk of Fire or Explosion! 

Gas  build-up 

during line purge could ignite. 

•  A small amount of air will be in the gas supply lines. 

•  Ensure adequate ventilation. 
•  Ensure there are no ignition sources such as sparks or 

open flames.

Light the appliance. It will take a short time for air to purge 

from lines. When purging is complete the appliance will 

light and operate normally.

WARNING! Risk of Fire, Explosion or Asphyxiation! 

Check  all  fittings  and  connections  with  a  non-corrosive 

commercially available leak-check solution. 

DO NOT

 use 

open  flame.  Fittings  and  connections  could  have  loos-

ened during shipping and handling.

•  Verify inlet pressures. Verify minimum pressures when 

other household gas appliances are operating. 

•  Install regulator upstream of valve if line pressure is 

greater than 1/2 psig.

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 in. w.c.

11.0 in. w.c.

Maximum inlet pressure

10.0 in. w.c.

13.0 in. w.c.

Manifold pressure

3.5 in. w.c.

10.0 in. w.c.

Note: 

Have the gas supply line installed in accordance with 

local codes, if any. If not, follow ANSI 

Z

223.1. Installation 

should be done by a qualified installer approved and/or 

licensed as required by the locality. (In the Commonwealth 

of Massachusetts installation must be performed by a 

licensed plumber or gas fitter).

Note: 

A listed (and Commonwealth of Massachusetts ap-

proved) 1/2 in. (13 mm) T-handle manual shut-off valve 

and flexible gas connector are connected to the 1/2 in. (13 

mm) control valve inlet. 

•  If substituting for these components, please consult 

local codes for compliance.

Fire Risk.
Risk of Fire!  Risk of Explosion!

Incorrect pressure will damage valve.
•  Isolate gas supply piping BEFORE pressure 

testing gas line at test pressures above 1/2 

psig.

•  Close the manual shutoff valve BEFORE 

pressure testing gas line at test pressures 

equal to or less than 1/2 psig.

WARNING

D.  High Altitude Installations

NOTICE: 

If the heating value of the gas has been reduced, 

these rules do not apply. Check with your local gas utility 

or authorities having jurisdiction.

When installing above 2000 feet  elevation:
•  In the USA: Reduce input rate 4% for each 1000 feet  

above 2000 feet.

•  In  CANADA:  Input  ratings  are  certified  without  a 

reduction of input rate for elevations up to 4500 feet 

(1370 m)above sea level. Please consult provincial and/

or local authorities having jurisdiction for installations at 

elevations above 4500 feet (1370 m).                                   

Check  with  your  local  gas  utility  to  determine  proper 

orifice size.

•  Optimum appliance performance requires proper input 

pressures.

•  Gas line sizing requirements will be determined in ANSI 

Z223.1 National Fuel Gas Code in the USA and CAN/

CGA B149 in Canada.

•  Pressure requirements when in operation are:

Содержание MARQUIS MARQ36IN-B

Страница 1: ...nstalled for the protection of children and other at risk individuals DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if y...

Страница 2: ...E Use of Elbows 18 F Measuring Standards 18 F Measuring Standards 19 G Vent Diagrams 20 G PVLP SLP and PVI SLP B Information 26 5 Vent Clearances and Framing A Pipe Clearances to Combustibles 27 B Wal...

Страница 3: ...ified attic insulation shield is installed if applicable ___________________ Verified Exterior wall Roof flashing is installed and sealed ___________________ Verified termination cap is installed and...

Страница 4: ...ally wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electric Code CSA C22 1 A 110 120 VAC ci...

Страница 5: ...gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local...

Страница 6: ...1 4 in Plumb line Safety glasses Gloves Wrenches Reciprocating saw 1 4 in nut driver Non corrosive leak check solution 1 2 3 4 in length 6 or 8 Self drilling screws Caulking material 300 F minimum co...

Страница 7: ...on Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged i...

Страница 8: ...le MARQ36IN B A B D C E I L M N O P R Q GAS ACCESS ELECTRICAL ACCESS J K HEAT MANAGMENT SYSTEMS ACCESS BOTH SIDES S diameter H F G T U HEAT MANAGMENT SYSTEMS ACCESS BOTH SIDES S diameter APPLIANCE DIM...

Страница 9: ...Appliance Dimensions Table MARQ42IN B Figure 3 2 Appliance Dimensions MARQ42IN B APPLIANCE DIMENSION DIAGRAM MARQ42IN B Location Inches Millimeters L 65 5 16 1659 M 16 406 N 32 11 16 830 O 3 7 8 98 P...

Страница 10: ...GRAM Figure 3 3 Decorative Barrier Front Dimensions See Section 10 for facing and finishing detail 1 5 16 IN 33 mm 3 5 8 IN 92 mm 40 11 16 IN 1033 mm 36 13 16 IN 935 mm 35 9 16 IN 903 mm FSMQ36 MARQ36...

Страница 11: ...ppliance should be lo cated out of traffic and away from furniture and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not draw...

Страница 12: ...n Combustible Zone NO COMBUSTIBLES IN HATCHED AREA 1 2 IN BUILDING MATERIAL MAY BE COMBUSTIBLE FACTORY SUPPLIED 1 2 IN NON COMBUSTIBLE BOARD PIPE IS FOR VISUAL REFERENCE ONLY 1 IN COMBUSTIBLES NOT ALL...

Страница 13: ...utside building envelope in any manner Walls ceiling base plate and cantilever floor of the chase should be insulated Vapor and air infiltration barriers should be installed in the chase as per region...

Страница 14: ...ight Rough Opening Height Rough Opening Depth Rough Opening Width Clearance to Ceiling MARQ36IN B Inches 10 56 80 3 8 24 59 1 2 52 Millimeters 254 1422 2042 610 1511 1321 MARQ42IN B Inches 10 61 85 3...

Страница 15: ...red the appliance must be raised by the equivalent height to ensure that the hearth extension does not interfere with the installation of the glass assembly required for fireplace operation See Figure...

Страница 16: ...nce is only approved for use with Hearth Home Technologies DVP or SLP venting systems Re fer to Section 12 A for vent component information and dimensions DO NOT mix pipe fittings or joining methods f...

Страница 17: ...he combustion air inlet to any other appliance termination mechanical or non mechanical 12 in 305 mm 12 in 305 mm I Clearance to a mechanical powered air supply inlet All mechanical air intakes within...

Страница 18: ...ches Millimeters DVP4 4 102 2 3 4 70 DVP6 6 152 4 1 4 108 DVP12 12 305 8 1 2 216 DVP24 24 610 17 432 DVP36 36 914 25 1 2 648 DVP48 48 1219 34 864 DVP6A 3 to 6 76 to 152 2 1 8 4 1 4 54 108 DVP12A 3 to...

Страница 19: ...e Section 12 A Figure 12 1 for information on effective length of pipe components Horizontal terminations are measured to the outside mounting surface flange of termination cap see Figure 4 7 Vertical...

Страница 20: ...ane MARQ42IN B NG V1 Minimum H1 Maximum 2 ft 610 mm 7 in 178 mm 2 5 ft 762 mm 17 in 432 mm 3 ft 914 mm 2 ft 610 mm 4 ft 1 2 m 4 ft 1 2 m 5 ft 1 5 m 9 ft 2 7 m 6 ft 1 8 m 12 ft 3 7 m 7 ft 2 1 m 14 ft 4...

Страница 21: ...ft 1 2 m 3 ft 914 mm 5 ft 1 5 m 7 ft 2 1 m 6 ft 1 8 m 10 ft 3 0 m 7 ft 2 1 m 14 ft 4 3 m 8 ft 2 4 m 16 ft 4 9 m 9 ft 2 7 m 18 ft 5 5 m 10 ft 3 0 m 20 ft 6 1 m V1 H1 H2 60 ft Maximum H1 H2 20 ft Maxim...

Страница 22: ...X V2 7 ft 2 1 m 14 ft 4 3 m H2 Max 2 X V2 10 ft 3 0 m 20 ft 6 1 m H2 Max 2 X V2 Shaded area of chart is for MARQ42IN B Propane V1 H1 must be adhered to V2 has no specific restrictions EXCEPT Ht max 2...

Страница 23: ...the system with the chart to find the appropriate position to set the exhaust restrictor See Table 4 1 5 Center the two exhaust restrictor pieces on the vent at the setting selected in step 3 and secu...

Страница 24: ...0 ft 15 2 m Max After V1 6 ft then H1 Max V1 x 2 Note Flue restrictor is permit ted ONLY on 30 ft minimum vertical runs with no elbows H1 V1 V2 Two Elbows Top Vent Vertical Termination continued Figur...

Страница 25: ...tions EXCEPT after V1 6 ft then HTOTAL Max 2 x V1 VTOTAL HTOTAL 50 ft 15 2 m Max Note Flue restrictor is permit ted ONLY on 30 ft minimum vertical runs with no elbows INSTALLED HORIZONTALLY H1 H2 V1 V...

Страница 26: ...2 The power vent draft flow must be adjusted and set per the specifications in Table 4 2 Refer to the instructions provided with the PVLP SLP and PVI SLP B for more specific information Setting the P...

Страница 27: ...nstal lation of a horizontal termination cap Note Heat shields MUST overlap by a minimum of 1 1 2 in 38 mm DVP heat shield designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall...

Страница 28: ...round the vent Insulation must be kept back from the pipe to prevent overheating Figure 5 3 Installing Ceiling Firestop Figure 5 4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE O...

Страница 29: ...f the appliance See Figure 5 5 Remove the knockouts from the appliance with a tin snips Center the duct collar around the exposed hole and attach it to the appliance with 3 screws Note Do this BEFORE...

Страница 30: ...s the shipping location of the seal cap and heat shields Section 6 splatter guard and finishing templates Section 10 and the logs Section 11 2 Remove seal cap from top of appliance by removing one scr...

Страница 31: ...cure the appliance to the framing members See Figure 6 3 and Figure 6 5 for location of nailing tabs in shipping position Bend out side nailing tabs 90 degrees See Figure 6 4 Place the appliance into...

Страница 32: ...shipped fastened to the top surround Remove finishing templates prior to installing non combustible board Remove non combustible facing pieces from back of appliance See Figure 6 6 Install non combust...

Страница 33: ...er than 1 2 in 13 mm If predrilling screw holes DO NOT penetrate inner pipe All outer pipe joints must be sealed using one of the meth ods below including the slip section that connects directly to th...

Страница 34: ...nner flue is not required All unit collar pipe slip section elbow and cap outer flues shall be sealed B Assemble Slip Sections Slide the inner flue of the slip section into the inner flue of the pipe...

Страница 35: ...ted every 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance or after any elbow must be supported every 8 ft 2 44 m Horizont...

Страница 36: ...inst the pipe section Seal around the top of the storm collar See Figure 7 13 E Vertical Termination Requirements Install and Seal Metal Roof Flashing See minimum vent heights for various pitched roof...

Страница 37: ...ermination cap shown in Figure 7 14 Heat shields must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other se...

Страница 38: ...verlap of flue telescoping section is required Failure to maintain overlap may cause overheating and fire Vent termination must not be recessed in the wall Siding may be brought to the edge of the cap...

Страница 39: ...in the same wall box 8 Electrical Information Junction Box Installation The electrical junction box can be accessed three ways during installation 1 Through the side electrical access Remove two screw...

Страница 40: ...ess controls be used for their fea tures and functionality with the IntelliFireTM Touch igni tion system Figure 8 2 Junction Box Detail Electrical Service and Repair WARNING Risk of Shock Label all wi...

Страница 41: ...of Shock or Explosion DO NOT wire IFT controlled appliance junction box to a switched circuit Incorrect wiring will override IFT safety lockout Refer to Figure 8 3 or 8 4 IFT Wiring Diagram This appl...

Страница 42: ...BOX 110 120 VAC LED CONTROL RF MODULE ADAPTER I S 6 PIN RED BLK ORANGE PILOT GREEN MAIN GRN WHT BLK RED BLK RED BLK IFT RC400 REMOTE CONTROL RED BLK BRN BRN JUMPER WIRE BRN WIRE ASSEMBLY MODULE RESET...

Страница 43: ...or upstream of valve if line pressure is greater than 1 2 psig Gas Pressure Natural Gas Propane Minimum inlet pressure 5 0 in w c 11 0 in w c Maximum inlet pressure 10 0 in w c 13 0 in w c Manifold pr...

Страница 44: ...for minimum vertical maximum horizontal vent run for this appliance 2 ft vertical and 7 in horizontal MARQ36IN B and 3 ft vertical and 10 in horizontal MARQ42IN B Factory Pre Set Air Shutter Settings...

Страница 45: ...materials beyond the min imum clearances Comply with all minimum clearanc es to combustibles as specified in this manual Ma terials overlapping into non combustible zones could ignite and will interf...

Страница 46: ...thod The finishing template pieces are required for installations that require more than one inch thick finishing materials to be installed over the face of the factory supplied 1 2 inch non combustib...

Страница 47: ...MARQ42IN B Installation Manual 2614 980 Rev D 4 19 Note A thin layer of mortar may be applied over the visible non combustible board between finishing material and the fireplace opening Figure 10 5 Fi...

Страница 48: ...MIN FIREPLACE OPENING COMBUSTIBLE OR NON COMBUSTIBLE WALL 14 IN MIN COMBUSTIBLE COLUMN 6 IN MAX 1 2 IN BUILDING MATERIAL FACTORY SUPPLIED NON COMBUSTIBLE BOARD Figure 10 6 Combustible Mantel Leg and W...

Страница 49: ...ce 12 10 56 FIREPLACE OPENING 1 1 4 IN 1 2 IN NON COMBUSTIBLE MATERIAL MARQ36IN B MAX MIN Measurement from fireplace opening to bottom of appliance 35 3 16 IN MARQ36IN B Figure 10 11 Combustible Mante...

Страница 50: ...aintained with finishing material with thickness greater than 1 inch A B COMBUSTIBLE MATERIAL Figure 10 11 Inside Fit Decorative Barrier Fronts The decorative barrier fronts approved for use with this...

Страница 51: ...to the lower right corner of the appliance Remove tool by removing one screw See Figure 11 1 If glass clip removal tool becomes misplaced a cotter pin removal tool may be used 2 To disengage bottom g...

Страница 52: ...he bottom glass clip location The MARQ36IN B has three tabs and the MARQ42IN B has four tabs If the glass is not centered it cannot be installed proper ly Align the notch at the top center of the glas...

Страница 53: ...sawdust that may have accumulated inside the firebox or underneath in the control cavity E Lava Rock Placement 1 Apply the lava rock as shown in Figure 11 9 The lava is to be placed around the base he...

Страница 54: ...Teco Sil is shipped with the appliance To place Teco Sil Locate and open the bag of Teco Sil Spread Teco Sil evenly over bottom glass assembly See Figure 11 11 Turn ember lights on and fog Teco Sil to...

Страница 55: ...Log 2 2270 703 03 Log 3 2270 702 02 Log 4 2270 704 04 CAUTION Logs are fragile Carefully remove the logs from the packaging 1 3 4 5 6 7 Log 5 2270 706 06 Log 6 2271 707 17 Log 7 2271 705 15 Logs can b...

Страница 56: ...rear cross member of grate assembly Be sure that the log is pushed back against the two vertical tabs for proper placement See Figure 5 Figure 4 Figure 2 Figure 3 Figure 5 Figure 6 LOG PLACEMENT SLOTS...

Страница 57: ...Figure 10 Figure 12 Figure 13 Figure 8 Figure 11 Log 4 2270 704 See Log 4 in Figure 10 Position Log 4 between grate tine and firebox wall Rest the end of Log 4 on the flat area on Log 1 and pivot the...

Страница 58: ...7 Position Log 6 onto flat spots on Log 2 and Log 3 The locking feature in Log 6 will mate with the cleft in Log 2 See Figures 14 15 Log 7 2271 705 Position Log 7 in the center of the firebox mating w...

Страница 59: ...703 13 Log 3 2271 702 12 Log 4 2271 704 14 CAUTION Logs are fragile Carefully remove the logs from the packaging 1 3 4 5 6 7 Log 5 2271 706 16 Log 6 2271 707 17 Log 7 2271 705 15 Logs can be identifi...

Страница 60: ...ear cross member of grate assembly Be sure that the log is pushed back against two vertical tabs for proper placement See Figure 5 Figure 4 Figure 2 Figure 3 Figure 5 Figure 5 LOG PLACEMENT SLOTS 2 Fi...

Страница 61: ...n Figure 8 Log 3 will rest on recess in Log 1 and the pilot shield See Figure 9 Figure 9 Figure 10 Figure 12 Figure 8 Figure 11 Log 4 2271 704 See bottom of Log 4 in Figure 10 The two grooves will mat...

Страница 62: ...right front grate tine mating with the recess on Log 4 See Figure 13 14 Log 7 2271 705 Position Log 7 in the center of the firebox mating with recesses in Log 1 and Log 5 Log 7 will rest on top of Log...

Страница 63: ...m Setup Detailed instructions for electrical wiring and connec tions are provided in Section 8 Verify that the 3 Position switch on the IFT ECM is switched to the REMOTE position Detailed Operat ing I...

Страница 64: ...P Pipe see chart Effective Height Length 4 7 8 in 124 mm 13 mm 10 in 254 mm 1 1 2 in 38 mm 5 in 127 mm 12 in 305 mm UP DVP HVS Vent Support 12 in 305 mm 14 in 356 mm 1 in 25 mm 8 in 203 mm 6 in 152 mm...

Страница 65: ...m The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness...

Страница 66: ...OL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC Cap Brick Extension 13 7 8 in 352 mm 5 in 127 mm 11 7 8 in 302 mm DVP TRAPFL Flashing 26 in 660 mm...

Страница 67: ...WH100 PVI SLP B Power Vent Inline SLP LPC SLP Low Profile Cap Note Wire harnesses required to power the PVI SLP B connect to the appliance and are ordered separately from PVI SLP B Contact your dealer...

Страница 68: ...order Figure 12 5 PVLP SLP Vent Components PVLP HS Heat Shield 14 IN 356 mm 15 1 2 IN 394 mm 11 1 2 IN 292 mm 8 IN 203 mm 4 3 8 IN 112 mm 10 IN 254 mm 5 1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4...

Страница 69: ...oducts com Please contact your Majestic dealer with any questions or concerns For the location of your nearest Majestic dealer please visit www majesticproducts com B Accessories Install approved acce...

Отзывы: