60
Suction fan unplugged
►
Connect up suction fan
Storage room auger motor
unplugged
►
Connect up storage room motor
13.17 Ashbox full (Fault 5044) – Ash Warning (Fault 5053)
Display:
[5044] PE Ashbox full
Description:
Moter doesn’t reach the normal speed after 3 attempts.
Display:
[5053] PE Ash Warning
Description:
Ash-box nearly full
Cause and Remedy:
Ash-box full
►
Clear ash-box
Ash-box not completely
closed
►
Close ash-box
End-switch defect
►
Replace end-switch
13.18 Ball lock (Smart and Condens only – Fault 5045)
Display:
[5045] PE Ball lock
– Smart and Condens only
Description:
No pellets detected from capacitive sensor (KAP RA)
Cause and Remedy:
Pellet reserves depleted
►
Refill storage-Room / supply tank
Capacitve sensor RA
defect
►
Replace Capacitve sensor RA
13.21 Pellets Warning (Fault 5054)
Display:
[5054] PE 1 Pellets Warning
Description:
Measured pellets capacity (AE2) is below the threshold
Cause and Remedy:
Pellets nearly empty or
empty
►
Fill up with pellets
Sensor unpuged (AE2)
►
Connect plug
Parameter set incorrectly
►
Check settings in menu Level detection sys-
tem (protected access)
PE 603 USA_FA 1.0
Содержание AutoPellet Air TOUCH 17
Страница 42: ...42 Cable routing PE 603 USA_FA 1 0...
Страница 43: ...Cable routing 43 Installation Manual AutoPellet Air Furnace 17 28...
Страница 45: ...Wiring diagrams 45 Installation Manual AutoPellet Air Furnace 17 28...
Страница 46: ...46 Wiring diagrams PE 603 USA_FA 1 0...
Страница 47: ...Wiring diagrams 47 Installation Manual AutoPellet Air Furnace 17 28...
Страница 70: ...70 Pellet Furnace cautionary markings PE 603 USA_FA 1 0...
Страница 71: ...Pellet Furnace cautionary markings 71 Installation Manual AutoPellet Air Furnace 17 28...
Страница 72: ...72 Pellet Furnace cautionary markings Labeling 105x74 PE 603 USA_FA 1 0...
Страница 73: ...Pellet Furnace cautionary markings 73 Installation Manual AutoPellet Air Furnace 17 28...
Страница 74: ......
Страница 75: ......