Prerequisites for installing a pellet Furnace
11
5
5
Prerequisites for installing a pellet Furnace
You must fulfil the following conditions before operating a fully automatic pellet Furnace.
5.1 Guidelines and standards for installing a pellet Furnace
Overview of standards and guidelines applying to the installation of a pellet Furnace.
Check whether you need to obtain planning permission or approval from the authorities for installing a new
heating system or changing your existing system. Installation must meet all requirements for pellet fired hea-
ting systems in your specific location.
All equipment shall be installed in accordance with the instructions of the manufacturer and in a manner ac-
ceptable to the authority having jurisdiction by experienced personnel. When required by the authority ha-
ving jurisdiction, such personnel shall be licensed to perform this service.
In Canada, the installation of the solid fuel furnace shall comply with the applicable requirements of CSA
B365, and if changes are made to the installation of the oil furnace, these shall comply with CSA B139.
If changes are made to an electric furnace during the installation, the changes shall comply with the Canadian
Electric Code. Part 1.
5.2 Furnace room circulating air
The pellet Furnace is installed in the Furnace room.
1.
Safety instructions for the Furnace room
R
Riissk
k o
off ffiirre
e
Do not store flammable materials or liquids in the vicini-
ty of the pellet Furnace.
Do not permit unauthorised persons to enter the Furna-
ce room - Keep children away.
Do not operate with fuel loading or ash removal doors
open.
2.
Air supply and ventilation of Furnace room
The Furnace room must be fitted with air supply and ventilation openings (at least 31 inch²/200cm²).In
any case you must comply with the state and local regulations
3.
Damage due to frost and humid air
The Furnace room must be frost-proof to ensure trouble-free operation of the heating system. The tem-
perature of the Furnace room must not fall below 37°F and must not exceed 90°F. The air humidity in the
Furnace room must not exceed 70%.
4.
Danger for animals
Make sure that household pets and other small animals cannot enter the Furnace room. Fit mesh over any
openings.
5.
Flooding
If there is a risk of flooding, switch off the pellet Furnace and disconnect from the power supply before
water enters the Furnace room. You must have all components that come into contact with water re-
placed, before you start up the pellet Furnace again.
Installation Manual AutoPellet Air Furnace 17 — 28
Содержание AutoPellet Air TOUCH 17
Страница 42: ...42 Cable routing PE 603 USA_FA 1 0...
Страница 43: ...Cable routing 43 Installation Manual AutoPellet Air Furnace 17 28...
Страница 45: ...Wiring diagrams 45 Installation Manual AutoPellet Air Furnace 17 28...
Страница 46: ...46 Wiring diagrams PE 603 USA_FA 1 0...
Страница 47: ...Wiring diagrams 47 Installation Manual AutoPellet Air Furnace 17 28...
Страница 70: ...70 Pellet Furnace cautionary markings PE 603 USA_FA 1 0...
Страница 71: ...Pellet Furnace cautionary markings 71 Installation Manual AutoPellet Air Furnace 17 28...
Страница 72: ...72 Pellet Furnace cautionary markings Labeling 105x74 PE 603 USA_FA 1 0...
Страница 73: ...Pellet Furnace cautionary markings 73 Installation Manual AutoPellet Air Furnace 17 28...
Страница 74: ......
Страница 75: ......