8.7 Flue Dimensions
The standard horizontal flue kit allows for flue lengths between 270mm (10
5
/
8
"
) and 800mm (32"
) from elbow to terminal (
).
The maximum permissible equivalent flue length is: 4 metres.
NOTE: Each additional 45° of flue bend will account for an equivalent flue length of 0.5m.
e.g. 45° = 0.5m,
90° = 2 x 45° = 1m etc.
Fig. 18
Fig. 18a