Maintenance and Inspection
13.6 Down stop catch pawl adjustme nt
The down stop catch pawl position should only be
adjusted if it is found to be outside of the adjustment range
described below. The following steps describe how to
check and adjust (if necessary) the down stop catch pawl
position
.
Checking the down stop catch pawl position
1.
Turn the master on/off switch to the
ON
position
.
2.
The green light shown in Fig. 21, Pos. 1 should be on
.
3.
Open the door and push down on the manual
raise/lower toggle switch (Fig. 17, Pos. 2). You should
hear the down stop catch pawl move backward, the
yellow light should illuminate, and the green light should
turn off while the toggle switch is held down
.
4.
If the down stop catches pawl and the lights responded
correctly, then no adjustment is necessary. Otherwise,
continue with the following steps to adjust the down
stop catch pawl position
.
Adjusting the down stop catch pawl position
1.
Disconnect the electrical connectors from the wire on
the green and yellow lights. These wires are found
inside the door behind the lights.
2.
Remove the top cap cover by loosening the 4 screws
shown in Fig. 21, Pos. 2 and then lifting up on the cover
to remove it
.
Fig. 21: Checking down stop catch pawl position
1
Green light
2
Screw
3
Screw
4
Top cap cover
5
Yellow light
6
Screws
3.
Loosen the four screws shown in Fig. 22 holding the
down stop solenoid in position so the solenoid can slide
forward and backward
.
4. Rotate the down stop catch pawl backward toward
the inside of the column (as shown by the arrow in
Fig. 22) until it touches the inside of the column. Hold
the pawl in this position.
Fig. 22: Adjusting down stop catch pawl position
1
Down stop catch pawl
2
Down stop solenoid
3
Screws
5.
Slide the down stop solenoid forward until a click is
heard from the switch on the down stop solenoid. Once
a click is heard, the down stop catch pawl can be
released
.
6.
Tighten the 4 screws holding the down stop solenoid to
lock it into position
.
7.
Rotate the down stop catch pawl backward and make
sure a click is again heard from the switch on the down
stop solenoid
.
8.
If a click is heard during the previous step, the down
stop catch pawl position is correct. Reinstall the top
cover. If a click is not heard, repeat steps 3-7
.
9.
Check the down stop solenoid positioning by
following steps 1-4 in the “Checking the down stop
catch pawl position” section. This will confirm the
adjustment was completed successfully
.
Содержание CML-7
Страница 38: ...Maintenance Chart CML Series 38 en Action Date Details Person responsible...
Страница 39: ...en 39 CML Series Notes 16 Notes...
Страница 40: ...Notes CML Series 37 Notes CML Series 40 en...
Страница 41: ...en 41 CML Series Notes...
Страница 42: ...en 42 CML Series Notes...
Страница 43: ...en 43 CML Series Notes...