37
BA022301-en
Special Features
•
When exiting the roller set, the test stand returns automatically to Standard
mode.
•
Repeat measurement: After measurement of the left-hand and right-hand
wheels the rollers are at a standstill. Now storage is possible, or the measure-
ment can be repeated with the green key, or the Parking brake can be tested.
•
Outside of the roller set the DCO can be activated with “Auto Off“ key (L) and
the arrow-up key (Y). Confirm with the star key (M). DCO lamp starts flashing.
This saves from doing the start-up monitoring twice in the roller set.
•
After 3 start-up monitorings the rollers stop and the tester changes from Drive
Control Mode to manual standard mode. Motors can be started individually via
the remote control. The display shows DC as optical help (Fig. B).