VIEW / RESET TOTALS
Note that if you are retrieving totals through the MLAN Protocol or the G2 Software, resetting totals is not
recommended unless you are factoring in a reset of this value back to zero.
Totals can be viewed or reset from two locations. Pressing the VIEW on the keypad key will display current totals and
cycle count. Pressing 00 from this screen will attempt to write totals to a USB flash drive and then reset totals and
cycles back to zero. Pressing any other non-zero value will cause the controller to write totals to a USB drive. There
must be a folder named "maguire" on the USB key for the print job to write the file printer.txt within that folder. Totals
can also be viewed or reset from the menu system.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will say:
ENTER PASSWORD _ _ _ _
Enter
2222
Default password is 2222
Press
down to VIEW / RESET TOTALS
Press
ENTER
to display the View / Reset Totals screen. This screen will display current
totals and cycle count. Press BACK to exit without clearing totals and
cycles.
Press
00
to reset the Totals (total grams dispensed since the last clear) and
Cycle Count back to zero. If no key is detected, the controller will
display "Failed to print, Continue Clearing Totals?" Press ENTER to
confirm.
Press
BACK
three more times to exit SETUP and go back to the Main Screen
RESTORE DEFAULTS
The MGF can be restored back to factory defaults by entering SETUP and scrolling down to RESTORE DEFAULTS,
highlight and press enter.
Standard 1" Diameter Feeder and Standard ½" Diameter Feeder WITHOUT Loader Option
Defaults for Standard 1" Diameter Feeder
MOTOR FACTOR
Stepper motor: 15.00, 1st Gen 26 RPM: 300 or 41 RPM: 500
ER FACTOR
1.0000
WEIGHT ERROR
20 g
LOW WEIGHT
0 LB
PASSWORD
2222
MODE
CONTINUOUS
UNITS
US
Defaults for ½" Diameter Feeder
MOTOR FACTOR
Stepper Motor: 02.50, 1st Gen 26 RPM: 77 or 41 RPM: 75
ER FACTOR
1.0000
WEIGHT ERROR
20 grams
LOW WEIGHT
0 LB
PASSWORD
2222
MODE
CONTINUOUS
UNITS
US
Standard 1" Diameter Feeder and Standard ½" Diameter Feeder WITH Loader Option
"MAIN MENU" SET-UP with Loader Option
LBS / HOUR
200
LDR
2 %
LOADER SETTINGS
TURN "ON" AT
2 LBS (907 grams)
TURN "OFF" AT
5 LBS (2268 grams)
ALARM TIME
120 seconds
"EQUIPMENT MENU" SET-UP with Loader Option
MOTOR FACTOR with 1” Diameter Feeder
Stepper motor: 15.00, 1st Gen 26 RPM: 300 or 41 RPM: 500
MOTOR FACTOR with ½” Diameter Feeder
Stepper motor: 2.50, 1st Gen 26 RPM: 77 or 41 RPM: 75
ER FACTOR
1.0000
WEIGHT ERROR
20 gram
LOW WEIGHT
0 LB
PASSWORD
2222
MODE
CONTINUOUS
LOADER
ON
UNITS
US
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...