PARAMETERS
All Maguire MGF controllers operate according to certain internal PARAMETERS. Because customer requirements
vary widely, we have made parameters accessible for change through the keypad. In most cases, these parameters
will never need to be changed. Some parameters that are routinely adjusted values are adjustable from the main
display.
LDR
SHT
PHR
FUL
PRT
KDF
LCZ
MTF
XCV
XMO
LBE
UBE
NBW
LWA
ATP
RTU
ADJ
LLF
LHF
LAT
STL
Let Down Ratio
Shot Weight
Per Hour Rate
Full Bin Weight
Report Interval
Stable Weight
Load-cell Zero
Motor Factor
Extruder Voltage
Extruder Max Output
Lower Boundary Error
Upper Boundary Error
Negative Bin Weight
Low Weight Alarm
Adjustment Trip Point
Run Time Update
Adjustment Limit
Loader Low Level
Loader High Level
Loader Alarm Timeout
Loader Settle Time
NWA
XMR
SPR
RPM
PMR
LCT
BFS
RCP
WKO
OPR
NMA
LIW
RAP
LLC
TAT
XFT
LCL
LCH
HRT
ECT
IPC
ISP
No Weight Adjustment
Extruder Minimum Rate
Steps Per Revolution
Maximum Revolutions Per Minute
Prime Motor Rate
Load Cell Tolerance
Bin Full Settle
Recipe Number
Work Order Number
Operator Number
No Meter Alarm
LIW Polling Rate
Rate Adjust Percentage
LIW Lower Cap
Target Adjust Threshold
Extrusion Voltage Filter
Loadcell Low
Loadcell High
High Rate Trip Point
Error Count Tracking
Injection Color Percent
Injection Screw Time Percent
LDR
Let Down Ratio – Percent
Factory Default - MGF-4: 00200, MGF-8: 00200
Percentage of SHOT WEIGHT or PER HOUR RATE in 1/100
th
percent
SHT
Shot Weight – Grams
Factory Default - MGF-4: 00200, MGF-8: 00200
Shot weight dispensed during cycle mode in whole grams
PHR
Per Hour Rate – Counts Per Hour
Factory Default - MGF-4: 00200, MGF-8: 00200
Value used to hold LB / HR or KG / HR depending on US / METRIC flag in whole units
FUL
Full Bin Weight – Grams
Factory Default - MGF-4: 10000, MGF-8: 10000
Weight of bin (hopper) when full, in whole grams. (Intended for future use)
PRT
Report Interval – Minutes
Factory Default - MGF-4: 00000, MGF-8: 00000
Used to generate reports while running.
In Continuous or extrusion following: reports are generated every X minutes. (00005 = every 5 minutes)
In Cycle Mode 00001 will enable printout of every cycle.
KDF
Stable Weight – Number
Factory Default - MGF-4: 00200, MGF-8: 00200
Used in load-cell calibration routine. Difference between raw count updates use to get a stable
reading. raw counts
LCZ
Load-cell Zero – Number
Factory Default - MGF-4: 20000, MGF-8: 20000
Lowest possible raw count value from loadcells for zero calibration. raw counts
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...