M A G U I R E P R O D U C T S , I N C .
26
G R A V I M E T R I C A U G E R F E E D E R
COMMUNICATIONS
Communications to and from the MGF use the MLAN Protocol and allow control of settings and parameters
as well as data and totals collection from the MGF.
MLAN ID
Sets the MGF’s Identification Number
Select this option to enter an identification number for this particular feeder. If you are
using communications to automatically gather data, then each controller must have a
unique address. Valid numbers are 001 to 254. All communication commands (MLAN
Protocol) use this I.D. number. For more information on communications, contact
Maguire Products, Inc. or see the Maguire MLAN Protocol manual available online at
www.maguire.com
.
VIEW MAC ADDRESS
View the MGF’s Ethernet MAC Address
VIEW TCP/IP ADDR
View the MGF’s TCP/IP Settings
Use the arrow keys to toggle through IP Address, Network Mask and Default Gateway.
TCP/IP SETUP
Set the Blender TCP/IP Settings
Used to set the IP Address, Network Mask and Default Gateway. Press the ENTER
key to toggle between DHCP and static IP Address. To set a Static IP Address, use
the keypad to enter the static IP address you wish to assign the controller and use
leading zeros when necessary. After entering the IP, the display will go to Network
Mask (Subnet), then to Default Gateway. After entering the Default Gateway, the
display will return to Static IP. When you are finished entering the network information,
press BACK to save settings and BACK 3 more times to go back to the main screen.
LOADER OPERATIONS:
LOADER
ON / OFF – Enable or Disable use of the Loader
LOADER ON WT
Loader On Weight, Grams – Weight in grams to turn on the loader
LOADER OFF W
Loader Off Weight, Grams - Weight in grams to turn off the loader
LOADER ALARM
Alarm in seconds – Alarm after the elapse of seconds if loader off weight is not satisfied.
METERING RATE:
MOTOR FACTOR:
Motor factor works in combination with auger size and the motor rpm. The motor factor
represents grams per revolution and the ½ inch auger uses a motor factor of 02.50 while the
1 inch auger uses a motor factor of 15.00. If you change the auger size, you must also
change the motor factor.
ADJUST. TRIP:
This is the trip point of percentage deviation from target grams per minute dispense in a
trend that triggers a readjustment of motor speed (5% default). Same as ATP parameter.
WEIGHT ERROR:
If hopper weight has not dropped at all after this amount of expected metering, the NO
METERING alarm will sound. This number should not be set too low as false alarms may
occur.
LOW WEIGHT:
This is weight, below which you want to receive an alarm. For example, set to 2 pounds, the
alarm will begin when remaining weight falls below 2 pounds. When set to 0, this alarm is
disabled.
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...