M A G U I R E P R O D U C T S , I N C .
16
G R A V I M E T R I C A U G E R F E E D E R
OVER WEIGHT LIMIT ALARM - ALARM CODE:52
This alarm indicates that the weight being read by the load cells exceeds the
capacity of the cells. The cells are 10 Kilos each, 20 Kilos total, about 44 pounds.
The hopper holds about 1/5 cubic foot, about 10 pounds. The weight of the
hopper when empty is about 8.2 pounds.
MOTOR CAPACITY
EXCEEDED - ALARM CODE:53
This alarm indicates that the calculated rate exceeds capacity.
The following variables effect the motor off-time calculation
MTF
(Motor Factor)
LDR
(Let Down Ratio)
PHR
(Per Hour Rate) (continuous and extr. Follow only)
SHT
(Shot Weight) (cycle mode only)
RATE ADJ
If the target rate calculates out to less than a step every 2 ms, then this alarm is triggered.
The following variables effect the motor step time calculation
MTF
(Motor Factor)
RPM
(Maximum RPM)
SPR
(Steps per Revolution)
LDR
(Let Down Ratio)
PHR
(Per Hour Rate) (continuous and extr. Follow only)
SHT
(Shot Weight) (cycle mode only)
RATE ADJ
BIN REMOVED - ALARM CODE:54
This alarm indicates that the hopper is not installed on the load cells. When this
alarm is active, the MGF will not allow the auger to run and will not allow the
loader to load material. Alarm is triggered if the bin weight falls below the NBW
(Negative Bin Weight) grams.
MAX ADJUST RATE - ALARM CODE:55
Indicates Motor factor is too low which causes the MGF to dispense too much
material over time, causing the rate adjust limit to reach 3.000. When the MGF
makes a correction, the RATE ADJ value is re-calculated to compensate for the
accumulated error. If the new RATE ADJ rises above the UBE (Upper Boundary
Error) (Defaulted to 300 = 3.00), then this alarm is triggered. Doing a prime
calibration is recommended and this will set your motor factor and rest rate adjust
to 1.000.
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...