M A G U I R E P R O D U C T S , I N C .
29
G R A V I M E T R I C A U G E R F E E D E R
LLF
Loader Low Level – whole grams
Factory Default - MGF-4: 00500, MGF-8: 00500
Weight of hopper that triggers the loader to turn on, whole grams
LHF
Loader High Level – whole grams
Factory Default - MGF-4: 02000, MGF-8: 02000
Weight of hopper that triggers the loader to turn off, whole grams
LAT
Loader Alarm Timeout – whole seconds
Factory Default - MGF-4: 00120, MGF-8: 00120
if the loader runs for this many seconds, the loader running too slowly alarm is tripped
STL
Loader Settle Time – Seconds
Factory Default - MGF-4: 00010, MGF-8: 00010
Number of seconds after loader finished before correction accumulators are readjusted and error
checking resumes. Whole seconds
NWA
No Weight Adjustment – Grams
Factory Default - MGF-4: 00100, MGF-8: 00100
If the material in the hopper goes below this value in grams, stop making adjustments to error
correction.
XMR
Extruder Minimum Rate – Grams/Second
Factory Default - MGF-4: 00000, MGF-8: 00000
For Extrusion control only – When a value is specified, this is the minimum rate (grams per
second) that the MGF will run when the extruder slows down.
SPR
Steps Per Revolution – Number - DO NOT CHANGE THIS PARAMETER
Factory Default - MGF-4: 06400, MGF-8: 06400
Stepper motor micro steps per revolution. With a current MGF motor, there are 200 step per
revolution and 32 hardwired micro steps or 6400 (200 x 32).
RPM
Maximum Revolutions Per Minute - Number - DO NOT CHANGE THIS PARAMETER
Factory Default - MGF-4: 00100, MGF-8: 00100
Software defined maximum number of revolutions per minute based on hardware capabilities.
PMR
Prime Motor Rate
Factory Default - MGF-4: 00020, MGF-8: 00020
Software defined maximum number of revolutions per minute when running the Prime Function. A
slower speed is used during PRIME to prevent overfills.
LCT
Load Cell Tolerance - GEN5 only. GEN6 does not use this parameter.
Factory Default - MGF-4: 00505, MGF-8: 00505
This parameter has 2 parts, xxx.yy. The left three digits (xxx) are the number of sequential raw
count readings before snapping to the new value (00505 = 5 sequential readings). The right two
digits (yy) are the difference between 2 sequential raw count readings (00505 = 5 raw counts) if
the latest raw count reading is less than yy, then continue to use the previous reading however, if
xxx readings in a row are the same value, then use to the latest reading.
BFS
Bin Full Settle - stepper motor only
Factory Default - MGF-4: 00020, MGF-8: 00020
If the bin weight spikes ± BFS grams beyond the target rate, then LOAD will appear and error
correction is halted until the bin weight settles again.
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...