M A G U I R E P R O D U C T S , I N C .
25
G R A V I M E T R I C A U G E R F E E D E R
Scale Calibration
Periodic zero and full calibration ensures that the MGF is weighing correctly. Calibration is also
necessary if a load cell is replaced or if the controller is replaced. Before doing a calibration, you
will need a known weight that can be rested on top of the hopper lid. The known weight must
weigh approximately 4000 grams and you must know exactly how many grams it actually weighs.
This weight in grams will be entered into the MGF. Also be sure of the following:
BE SURE
the material hopper is EMPTY.
BE SURE
the load cell connector is plugged into the side of the controller.
BE SURE
the LOADER material hose is connected to the hopper lid.
Calibration Sequence:
Turn the MGF on. View the Main Menu screen on the LCD window.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will show:
ENTER PASSWORD _ _ _ _
Press
To scroll down to
SCALE CALIBRATION
Press
ENTER
Display will show:
ZERO CALIBRATION
FULL CALIBRATION
ZERO CALIBRATION
is selected and should be done first, followed by a
FULL CALIBRATION
Press
ENTER
Display will show:
WARNING - If this calibration is not performed
properly it may disable your scale.
Press
ENTER
Display will show:
LOAD CELL ZERO, WAIT followed by,
CALIBRATION SUCCESSFUL
Press
To scroll down to
FULL CALIBRATION
FULL CALIBRATION - Place your known calibration weight on top of the hopper lid.
Press
ENTER
Display will show:
WARNING - If this calibration is not performed
properly it may disable your scale.
Press
ENTER
Display will show:
LOAD CELL FULL, Enter Weight:
Enter the weight in grams of your calibrated weight.
Enter
the weight in whole grams of your calibration weight.
NOTE: The MGF field has 5 digits, use a leading zero when entering a 4-digit value.
Press
ENTER
Display will show:
LOAD CELL FULL, WAIT followed by,
CALIBRATION SUCCESSFUL
Press
BACK
three times to return to the Main Menu. Main Menu screen should display
0 (zero) at the bottom of the display. If the display does not show 0 (zero),
repeat ZERO and FULL calibration routine. With the weight still on the
hopper, the display should read the correct weight value in whole grams.
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...