M A G U I R E P R O D U C T S , I N C .
30
G R A V I M E T R I C A U G E R F E E D E R
RCP
Recipe Number - Number
Factory Default - MGF-4: 00000, MGF-8: 00000
Recording purposes only, set the MGFs recipe number returned in the MLAN commands.
This field stores a 5-digit number 00000-99999.
WKO
Work Order Number - Number
Factory Default - MGF-4: 00000, MGF-8: 00000
Recording purposes only, set the work order number returned in the MLAN commands.
This field stores a 5-digit number 00000-99999.
OPR
Operator Number - Number
Factory Default - MGF-4: 00000, MGF-8: 00000
Recording purposes only, sets the operator number returned in the MLAN commands.
This field stores a 5-digit number 00000-99999.
NMA
No Metering Alarm - Continuous mode only
Factory Default - MGF-4: 33500, MGF-8: 33500
This parameter has 3 parts: x.y.zzz
Leftmost digit (x) is the number of times the rate is below the threshold before the alarm is turned
on (33500 = 3 counts). Second digit from the left (y) is the number of times the rate is above the
threshold before the alarm is turned off (33500 = 3 counts). The rightmost 3 digits (zzz) are the
percentage of target rate (1/10th of a percent) (33500 = 50.0%).
LIW
LIW Polling Rate - LIW Mode only
Factory Default - MGF-4: 00010, MGF-8: 00010
The number of seconds between each poll of the LIW's steady rate. Faster rates may cause
issues with the ethernet stack. Slower rates may cause issues with the MGF detecting changes in
the LIW's steady rate.
RAP
Rate Adjust Percentage - Extrusion Following Only
Factory Default - MGF-4: 10050, MGF-8: 10050
This parameter has 2 parts, xx.yyy
The leftmore two digits (xx) are the number of seconds between each rate adjustment check
(10050 = 10 seconds). The three rightmost digits (yyy) are the lower threshold in grams per
minute (10050 = 5.0 g/m). If the target g/m rate falls below the yyy threshold, the time between
rate adjustment checks will change to xx. If the target g/m rate rise back above yyy threshold, the
time between rate adjustment checks will revert back to its original setting.
LLC
LIW Lower Cap
Factory Default - MGF-4: 00010, MGF-8: 00010
Used for MLAN commands and LIW polling for continuous mode only. Stored as 1/10th LBS or
KGS per hour (depending on the weight units setting) (00010 = 1.0 lb/hr). When a new target rate
is received, it is checked against the LLC parameter. If the rate is equal to or below LLC,
then the PHR parameter will snap to zero.
Содержание GRAVIMETRIC AUGER FEEDER MGF-ST
Страница 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R AGL Loader Diagram ...
Страница 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R MGF Wiring Diagrams ...
Страница 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Страница 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...