MICRSafe with 3-Track MSR
20
RD00<CR>
(to disable the use of the auxiliary RS-232 port)
or
RD01<CR>
(to enable the use of the auxiliary RS-232 port for transmitting MSR data
only)
or
RD02<CR>
(to enable the use of the auxiliary RS-232 port for transmitting check data
only)
or
RD03<CR>
(to enable the use of the auxiliary RS-232 port for transmitting both MSR
and check data)
If no data is sent, the MICRSafe responds with the current value of RD.
CHKCNT – CHECK COUNT COMMAND
This command returns the number of checks that have been processed by the device. To
execute, send the CHKCNT command followed by a carriage return as follows:
CHKCNT<CR>