53
APPENDIX C. TROUBLESHOOTING GUIDE
REQUIREMENTS
•
Personal Computer.
•
USB Cable, P/N 22553301
•
DC adapter, P/N 64300118 (64300121 for international customers).
•
MICRbase setup program, P/N 22000021.
•
Sample checks, P/N 96530005.
•
A small bottle of compressed air.
•
A cleaning card, P/N 96700006.
SET-UP
•
Plug the USB Cable, P/N 22553301, into the MICRSafe and the host computer.
•
Power on the MICR Reader.
•
Run the MICRbase program on the PC.
•
Start trouble-shooting procedure at Step 00.
00
CHECK LED
Check the status of the LED indicator:
◊
off, continue to step 01.
◊
green, continue to step 02.
◊
blinking red, continue to step 11.
◊
blinking red/green, continue to 12.
◊
red or orange, continue to step 18.