MICRSafe with 3-Track MSR
54
01
CHECK THE POWER TO THE MICRSAFE
Possible causes for this problem are:
•
DC adapter connection to outlet - make sure the DC adapter is securely connected to outlet
on the wall or power strip.
•
DC adapter connection to MICRSafe - make sure the DC adapter is securely connected to the
power jack on the MICRSafe.
•
Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and
the switch on the strip is turned on.
•
DC adapter is defective - replace the DC adapter.
Determine if any of the conditions described above are true:
◊
If yes, rectify and continue to step 00.
◊
If no, continue to step 18.
02
READ A CHECK
Read a check through the MICRSafe:
◊
If the check is transported all the way around the check path, continue to step 03.
◊
If the check gets "stuck" in the check path, continue to step 10.
◊
If the motor does not turn on, continue to step 18.
03
DID PC RECEIVE DATA?
After the check is read, did the PC receive any data?
◊
If yes, continue to step 04.
◊
If no, continue to step 05.
04
ANALYZE DATA
Analyze the data received by the PC:
◊
If the data is good, continue to step 16.
◊
If the data contains one or more '?', continue to step 06.
◊
If the data is missing characters, continue to step 07.
◊
If the data is garbled, continue to step 08.
◊
If the data is good but not what is expected, continue to step 09.
Содержание MICRSafe
Страница 8: ...viii Figure 1 1 MICRSafe with 3 Track MSR...
Страница 12: ...MICRSafe with 3 Track MSR 4...
Страница 50: ...MICRSafe with 3 Track MSR 42...
Страница 52: ...MICRSafe with 3 Track MSR 44...
Страница 56: ......
Страница 68: ...MICRSafe with 3 Track MSR 60...
Страница 70: ...MICRSafe with 3 Track MSR 62...
Страница 78: ...MICRSafe with 3 Track MSR 70...