3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Manual (Commands)
Page 50 of 128 (
D99875629-43
)
information about the bootloader is available in document
99200071 MNL DYNALEX
BOOTLOADER
.
To send new file data to the device, follow these steps:
1)
Command 0x10 - Send Big Block Data to Device
to send new file data to the device
2)
to request the device to validate and perform an update using
the file data with the correct parameters.
If an error occurs, the device will terminate the command and report the error in ACKSTS of
. For a full list of error codes, see
Appendix C Status and Message Table, Table
Table 3-24 - Usage Table for Command 0x17
Bit
7
6
5
4
3
2
1
0
Byte 0
0x17
Byte 1
Options. See
Byte 2..8
Reserved
Table 3-25 - Options for Command 0x17
Byte 1 Usage
7
6
5
4
3
2
1
0
Notes
Reset
Options
N/A
N/A
N/A
N/A
N/A
N/A
0
0
Return Response ACK
(big data must exist),
Update, Reset when
Done
N/A
N/A
N/A
N/A
N/A
N/A
0
1
Return Response ACK
(big data must exist),
Update, Delayed
Response ACK, Allow
Reset later
N/A
N/A
N/A
N/A
N/A
N/A
1
0
RFU
N/A
N/A
N/A
N/A
N/A
N/A
1
1
Return Response ACK,
wait 100ms, Reset
Now (only valid after
successful update)
RFU
X
X
X
X
X
X
N/A
N/A
RFU
3.4.21
Command 0x1A - Request Device Information
This command requests information about the device. Use this command in Set mode first to specify the
information to retrieve, then use Get mode to retrieve the requested information.