3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Manual (Commands)
Page 44 of 128 (
D99875629-43
)
Bit
7
6
5
4
3
2
1
0
Byte 4..63 Block data
Table 3-17 - Response for Command 0x0E
Info ID
Key Status
Data
length
Data
Description
0x00
1
lbllen*
Auth key label
If authorization key exists
0x01,0x02 2
20
KSN
If no more keys
0x01
1
20
KSN
PIN key
0x02
1
20
KSN
MSR key
0x03
1
<=59
SN & subject’s DN**
If PIN cert exists
0x04
1
<=59
SN & subject’s DN**
If MSR cert exists
0x05
1
<=19
Label and KCV
If authorization key exists
0x06
1
<=19
Label and KCV
If fixed key exists
0x08
1
12
Customer ID (4 byte
integer), Signing Sequence
Number (4 byte integer),
Upgradability Options (4
byte integer)
0x0000000 is Generic Customer
Signing Sequence typically starts
at 0x00000000 and must advance
with each upgrade.
Upgradability values:
0x00000000 = Generic Only
0x00000001 = Specific Only
0x00000002 = Generic or Specific
0x09
1
<=19
Label and KCV
Acquirer Master Key
0x10
1
4 x 3
4 slots for bitmap data
[ 2 bytes CRC]
status: 0 = not loaded
1 = loaded
Bitmap data status and its CRC
0x20 -
0x29
-
-
-
RESERVED
0x50
1
9
Keypad sensitivity
Tamper sensitivity
Key on threshold
Key off threshold
4 bytes keypad threshold
Keypad calibration result
Keypad values
(Cap Keypad Only)
0x60 -
0x70
1
<=59
SN & subject’s DN**
If associated CA cert exists***
0x71 -
0x7F
1
<=59
SN & issuer’s DN**