40
58-610 Model R82 Radar Transmitter
Display
Action
Comment
1
Factory Params
Select Enter to reveal Factory
Parameters; Back to escape.
Review Factory parameters
2
History
Displays history of diagnostic information
- Main screen displays active message
- Press Enter to display chronological listing of diagnostic events
- Use Up/Down arrows to view list of events
- Press Enter when viewing an event to see its timing information
- Press Up/Down arrows to view Occured or Duration
NOTE: Times are measured from moment of power-up, displayed
in seconds or tenths of an hour
- Press Back to exit
3
Run Time
Display Run Time
Displays elapsed time since most recent power-up.
4
History Reset
Reset History
Press Enter to clear diagnostic information in History and reset
Run Time to zero.
5
System Code
Displays System Code errors Diagnostic, factory setting
6
Elec Temperature
Display Electrical Temperature Displays current temperature on circuit board.
7
Max Temperature
Display Max Temperature
Displays maximum temperature recorded for circuit board.
8
Min Temperature
Display Min Temperature
Displays minimum temperature recorded for circuit board.
9
VDC Chk Midpoint
None, do not adjust
Diagnostic factory setting
10
Antenna Mount
None, do not adjust
Diagnostic factory setting
11
Echo Profile
None, do not adjust
Diagnostic factory setting
12
Target Algorithm
None, do not adjust
Diagnostic factory setting
13
TVG Minimum
None, do not adjust
Diagnostic factory setting
14
TVG Maximum
None, do not adjust
Diagnostic factory setting
15
Peak Detect Ref
None, do not adjust
Diagnostic factory setting
16
Peak Detect Thresh
None, do not adjust
Diagnostic factory setting
17
Min Threshold
None, do not adjust
Diagnostic factory setting
18
# Run Average
None, do not adjust
Diagnostic factory setting
19
# Adap Average
None, do not adjust
Diagnostic factory setting
20
Scatter HiLimit
None, do not adjust
Diagnostic factory setting
21
Rate HiLimit
None, do not adjust
Diagnostic factory setting
22
Scatter Rate
None, do not adjust
Diagnostic factory setting
23
Lvl ROC Per Min
None, do not adjust
Diagnostic factory setting
24
Max ROC Per Min
None, do not adjust
Diagnostic factory setting
25
Max Distance Jump
None, do not adjust
Diagnostic factory setting
26
Boundary State
None, do not adjust
Diagnostic factory setting
27
EmptyState Delay
None, do not adjust
Diagnostic factory setting
28
NSPValue
None, do not adjust
Diagnostic factory setting
29
HART Device ID
None, do not adjust
Diagnostic factory setting
30
Factory Calib
None, do not adjust
Diagnostic factory setting
31
Window
None, do not adjust
Diagnostic factory setting
32
Target Distance
None, do not adjust
Diagnostic factory setting
33
Conversion Factor
None, do not adjust
Diagnostic factory setting
34
Scale Offset
None, do not adjust
Diagnostic factory setting
35
System Gain
None, do not adjust
Diagnostic factory setting
2.6.6.4 Radar Transmitter Factory Menu