32
58-601 Pulsar
®
Radar Transmitter
3.4
Agency Approvals
FM
RX5-5X0A-1X0
Intrinsically Safe
Class
I
, Div. 1; Groups A, B, C, & D
Class
II
, Div. 1; Groups E, F, & G
Class
III
, NEMA 4X, T4 @80°C
Entity
RX5-5X0A-3X0
Explosion Proof
Class
I
, Div. 1; Groups B, C & D
Class
II
, Div. 1; Groups E, F, & G
Class
III
, NEMA 4X, T5 @80°C
RX5-5X0A-XX0
Non-Incendive
Class
I
, Div. 2; Groups A, B, C, & D
Class
II
, Div. 2; Groups F & G
Class
III
, NEMA 4X
CSA
RX5-5X0A-1X0
Intrinsically Safe
Class
I
, Div. 1; Groups A, B, C, & D
Class
II
, Div. 1; Groups E, F & G
Class
III
, Type 4X, T4 @80°C
Entity
RX5-5X0A-3X0
Explosion Proof
Class
I
, Div. 1; Groups B, C & D
Class
II
, Div. 1; Groups E, F, & G
Class
III
, Type 4X, T5 @80°C
RX5-5X0A-XX0
Non-Incendive
Class
I
, Div. 2; Groups A, B, C, & D
Class
II
, Div. 2; Groups E, F, & G
Class
III
, Type 4X, T4 @80°C
ATEX
R05-5X0A-AX0
Intrinsically Safe
ATEX
II
1G EEx ia
II
C T4 @70°C
IEC Ex ia
II
C T4@70°C
R05-5X0A-CX0
Explosion Proof
ATEX
II
1/2G EEx d
II
C T6 @70°C
AGENCY
MODEL
PROTECTION METHOD
AREA CLASSIFICATION
These units have been tested to EN 61326: 1997+A1+A2
and are in compliance with the EMC Directive 2004/108/EC.
COMMUNICATIONS APPROVALS
ATEX/IEC Entity Parameters
Region
Agency
Frequency
US
FCC
6.3 GHz
Canada
IC
6.3 GHz
Europe
RTTE
5.8 GHz
Vi
28.4VDC
li
120mA
Pi
0.84w
Ci
2.2nF
Li
430
µ
H
PULSAR
Model RX5
SIL
1 as 1oo1
Instrument Type
B
SFF
73.7%
PFDavg
9.72E-04
FITS
Annual
Fail Dangerous Undetected
222
1.94E-03
Fail Dangerous Detected
308
2.70E-03
Safe
314
2.75E-03
Measured media inside vessel must be non-flammable only.
The antenna complies with Canadian Electrical Code requirements
of ANSI/ISA 12.27.01-2003 as a single seal device.
Special conditions for safe use:
Ex ia
When an insulated probe is used in a potentially explosive atmosphere
caused by gas, damp or a non-conducting liquid, precautions must
be taken to avoid ignition due to hazardous electrostatic charges.
Ex d
When the transmitter enclosure that is made of aluminum alloy is
installed in a potentially explosive atmosphere, requiring the use of
apparatus of equipment category 1G, it shall be installed so that in
the event of rare incidents, an ignition source due to impact or friction
between the enclosure and iron/steel is excluded.
The transmitter’s antenna shall be installed so that electrostatic
discharges are prevented.
SIL
Содержание pulsar RX5
Страница 1: ...Pulse Burst Radar Level Transmitter Model RX5 RX5 software v2 1a Installation and Operating Manual ...
Страница 33: ...33 58 601 Pulsar Radar Transmitter 3 4 1 Agency FM CSA Drawing and Entity Parameters ...
Страница 46: ...58 601 Pulsar Radar Transmitter Notes ...