58-601 Pulsar
®
Radar Transmitter
3.3.2 Error Messages
The PULSAR Radar transmitter utilizes a 3-section hierarchy
for reporting diagnostic conditions: FAULTS, WARNINGS,
and INFORMATION. This information can be reviewed at
the STATUS screen in the user menu. This screen captures
only current conditions. Historical information can be
viewed at the DIAGNOSTIC screen in the Factory menu.
FAULT:
The highest level in the hierarchy of diagnostics
annunciating a defect or failure in circuitry or software that
precludes reliable measurement. The current (mA) value
unit defaults to 3.6, 22, or HOLD and a message is dis-
played on the rotating screen. Further error information can
be obtained by viewing the Status or Diagnostic (Factory
Menu) screens.
WARNING (MESSAGE):
The second level in the hierarchy
of Diagnostics annunciating conditions that are not fatal
but may affect measurement. A message will occur on the
main (rotating) screen when a Warning is detected but will
not affect output current. Further error information can be
obtained by viewing the Status or Diagnostic screens.
INFORMATION (MESSAGE):
The lowest level in the
hierarchy of diagnostic conditions providing operational
factors that are not critical to measurement. Further error
information can be obtained by viewing the Status or
Diagnostic (Factory Menu) screens.
mA Loop
Display Message
Diagnostic (history)
Fault
3.6/22/HOLD
Yes
Yes
Warning
No Effect
Yes
Yes
Information
No Effect
No
Yes
EFFECTS OF EACH DIAGNOSTIC MESSAGE