13
57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
• Use a grounding wrist strap when installing and removing
circuit boards. A grounded workstation is recommended.
• Handle circuit boards only by the edges. Do not touch
components or connector pins.
• Make sure that all electrical connections are completely
made and none are partial or floating. Ground all equip-
ment to a good, earth ground.
2.3
Before You Begin
2.3.1 Site Preparation
Each ECLIPSE Model 706 transmitter/probe is built to
match the physical specifications of the required installa-
tion. Ensure that the probe process connection is correct for
the threaded or flanged mounting on the vessel where the
transmitter will be placed. See Mounting, Section 2.4.
Ensure that all local, state, and federal regulations and
guidelines are observed. See Wiring, Section 2.5.
Ensure that the wiring between the power supply and
ECLIPSE transmitter is complete and correct for the type
of installation. See Specifications, Section 3.6.
2.3.2 Equipment and Tools
No special equipment or tools are required to install the
ECLIPSE transmitter. The following items are recommended:
• Open-end wrenches (or adjustable wrench) to fit the process
connection size and type.
•
Coaxial probe: 1
1
⁄
2
" (38 mm)
•
Twin cable probe: 1
7
⁄
8
" (47 mm)
•
Single Rod probe: 1
7
⁄
8
" (47 mm)
•
Transmitter 1
1
⁄
2
" (38 mm)
A torque wrench is highly desirable.
• Flat-blade screwdriver
• Cable cutter and
3
⁄
32
" hex wrench (for flexible cable probes
only)
• Digital multimeter or digital volt/ammeter
• 24 VDC power supply, 23 mA minimum
2.3.3 Operational Considerations
Operating specifications vary based on probe model
number. See Specifications, Section 3.6.