57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
2.4.6 Installing the ECLIPSE Model 706 Transmitter
The transmitter can be ordered for installation in three con-
figurations;
1) As an Integral version, mounted directly on to the probe.
2) As a Remote version, with the transmitter separated from
the probe by a distance of 3 feet (84 cm).
3) As a Remote version, with the transmitter separated from
the probe by a distance of 12 feet (366 cm).
NOTE Due to their extra weight, remote mounted transmitter Model
Number 706-xxxx-x2x is recommended for:
•
All applications utilizing the cast 316 SS enclosure
•
Those applications having potential vibration
2.4.6.1 Integral Mount
1. Remove the protective plastic cap from the top of the
probe. Store the cap in a safe place in case the transmitter
has to be removed later.
2. Place the transmitter on the probe. Do not allow the gold
pin in the high frequency connector or the gold socket on
the probe to get dirty.
3. Align the universal connection at the base of the transmitter
housing with the top of the probe. Only hand-tighten the
connection at this time.
4. Rotate the transmitter to face the most convenient direction
for wiring, configuration, and viewing.
5. When the transmitter is facing the desired direction, use a
1
1
⁄
2
" wrench to tighten the universal connection on the
transmitter to 45 ft-lbs (60 Nm). A torque wrench is highly
recommended. This is a critical connection. DO NOT
LEAVE HAND-TIGHT.
2.4.6.2 Remote Mount
1. Mount the transmitter/remote bracket as an assembly within
33" or 144" (84 or 366 cm) of the probe. DO NOT
REMOVE TRANSMITTER OR REMOTE CABLE
FROM THE MOUNTING BRACKET.
2. Remove the protective plastic cap from the top of the
probe. Store the cap in a safe place in case the transmitter
has to be removed later.
3. Align the universal connection at the end of the remote
assembly with the top of the probe. Using a 1
1
⁄
2
" wrench,
tighten the universal connection on the transmitter to 45 ft-
lbs (60 Nm). A torque wrench is highly recommended. This
is a critical connection. DO NOT LEAVE HAND-TIGHT.
¿
¡
¬
√
ƒ
¿
U-bolts not included