86
57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
1
|
TECHNOLOGY
2
|
MEASUREMENT SYSTEM
3
|
CONFIGURATION/STYLE (RIGID)
7
ECLIPSE GWR Probes - Model 706
A
English
C
Metric
G
Overfill Caged Rigid Probe for use in ch400 °F (+200 °C) —
Only available with 2
"
, 3
"
and 4
"
flanges
J
Overfill Caged High Temp/High Pressure Probe with Glass Seal for use in ch850 °F (+450 °C)
Only available with 2
"
, 3
"
and 4
"
flanges
L
Overfill Caged High Pressure Probe with Glass Seal for use in ch400 °F (+200 °C)
Only available with 2
"
, 3
"
and 4
"
flanges
Torque Tube Mating Flanges
¡
T T
600# Fisher (249B/259B) in carbon steel – as per dimensions on page 18
T U
600# Fisher (249C) in stainless steel – as per dimensions on page 18
U T
600# Masoneilan flange in carbon steel – as per dimensions on page 18
U U
600# Masoneilan flange in stainless steel – as per dimensions on page 18
4 5
|
PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections)
¿
¿
Confirm mounting conditions/nozzle diameter to ensure sufficient clearance.
¡
Always check dimensions if ANSI/EN flanges are not used.
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
EN Flanges
D A
DN 50, PN 16
EN 1092-1 TYPE A
D B
DN 50, PN 25/40 EN 1092-1 TYPE A
D D
DN 50, PN 63
EN 1092-1 TYPE B2
D E
DN 50, PN 100
EN 1092-1 TYPE B2
D F
DN 50, PN 160
EN 1092-1 TYPE B2
D G
DN 50, PN 250
EN 1092-1 TYPE B2
D H
DN 50, PN 320
EN 1092-1 TYPE B2
D J
DN 50, PN 400
EN 1092-1 TYPE B2
E A
DN 80, PN 16
EN 1092-1 TYPE A
E B
DN 80, PN 25/40
EN 1092-1 TYPE A
E D
DN 80, PN 63
EN 1092-1 TYPE B2
E E
DN 80, PN 100
EN 1092-1 TYPE B2
E F
DN 80, PN 160
EN 1092-1 TYPE B2
E G
DN 80, PN 250
EN 1092-1 TYPE B2
E H
DN 80, PN 320
EN 1092-1 TYPE B2
E J
DN 80, PN 400
EN 1092-1 TYPE B2
F A
DN 100, PN 16
EN 1092-1 TYPE A
F B
DN 100, PN 25/40
EN 1092-1 TYPE A
F D
DN 100, PN 63
EN 1092-1 TYPE B2
F E
DN 100, PN 100
EN 1092-1 TYPE B2
F F
DN 100, PN 160
EN 1092-1 TYPE B2
F G
DN 100, PN 250
EN 1092-1 TYPE B2
F H
DN 100, PN 320
EN 1092-1 TYPE B2
F J
DN 100, PN 400
EN 1092-1 TYPE B2
ANSI Flanges
4 3
2"
150# ANSI RF
4 4
2"
300# ANSI RF
4 5
2"
600# ANSI RF
4 7
2"
900/1500# ANSI RF
4 8
2"
2500# ANSI RF
4 K
2"
600# ANSI RTJ
4 M
2"
900/1500# ANSI RTJ
4 N
2"
2500# ANSI RTJ
5 3
3"
150# ANSI RF
5 4
3"
300# ANSI RF
5 5
3"
600# ANSI RF
5 6
3"
900# ANSI RF
5 7
3"
1500# ANSI RF
5 8
3"
2500# ANSI RF
5 K
3"
600# ANSI RTJ
5 L
3"
900# ANSI RTJ
5 M
3"
1500# ANSI RTJ
5 N
3"
2500# ANSI RTJ
6 3
4"
150# ANSI RF
6 4
4"
300# ANSI RF
6 5
4"
600# ANSI RF
6 6
4"
900# ANSI RF
6 7
4"
1500# ANSI RF
6 8
4"
2500# ANSI RF
6 K
4"
600# ANSI RTJ
6 L
4"
900# ANSI RTJ
6 M
4"
1500# ANSI RTJ
6 N
4"
2500# ANSI RTJ
3.7.4 Caged Probe