Swing Door
MPS-122
Commissioning and settings
48
2. Swivel the locking element to the desired home position.
3. Confirm the position by pushing the button again within the
next 10 seconds. The buzzer confirms the new homing
position with a continuous signal of 2 second.
NOTE!
If you do
not
push the button again within the next
10 seconds, the process will be cancelled. The
buzzer emits a signal at 2 Hz twice and the locking
element swivels back to its original home position.
The original home position remains valid.
4. After 3 seconds, the locking element automatically swivels to
the first end stop. The buzzer emits a signal at a cycle of 1 Hz
during the movement.
5. The locking element briefly remains in the first end position.
6. The locking element automatically swivels to the second end
stop. The buzzer emits a signal at a cycle of 1 Hz during the
movement.
7. The locking element briefly remains in the second end
position.
8. The locking element automatically swivels to the new home
position. The buzzer emits a signal at a cycle of 1 Hz during
the movement.
9. After one second, the buzzer emits two signals at 6 Hz.
The home position is set.
8.4.2
Setting the hold-open time
You may set the hold-open time using the button at the control unit.
Setting range: 1…25 s
Factory setting: 8 s
1. Push button three times within 5 seconds. The buzzer emits a
signal every time the button is pushed. After 5 seconds, the
buzzer emits a signal at 6 Hz twice.
NOTE!
If you do
not
push the button three times within
5 seconds, the process will be cancelled. The
original hold-open time remains valid. The buzzer
emits a signal at 2 Hz twice.
Содержание MPS-122
Страница 1: ...Operating Instructions Swing Door MPS 122 Doc ID 5817 0011EN Version 04...
Страница 6: ...Swing Door MPS 122 6 5817 0011EN Version 04...
Страница 85: ......